Clinical Trials Directory

Trials / Unknown

UnknownNCT03783806

Postural Control in Degenerative and Inflammatory Diseases of the Hip

Status
Unknown
Phase
Study type
Observational
Enrollment
90 (estimated)
Sponsor
Szeged University · Academic / Other
Sex
All
Age
Healthy volunteers
Accepted

Summary

Patients with primary hip osteoarthritis (OA group) and patients with inflammatory hip disease (RA group) and healthy subjects (control group) are enrolled in the study. The aim of our study is to determine the postural control in patients suffering from OA and RA of the hip joint during different conditions, i.e., on both stable and compliant surfaces with opened or closed eyes to determine the possible differences between these two diseases in this respect.

Detailed description

Determination of functional status, using the following outcome measures: Harris Hip Score, the Functional status of the hip joint is rated with the Harris Hip Score (HHS), Visual Analogue Scale, Western Ontario and McMaster Universities Osteoarthritis Index, Timed Up \& Go test. Posturography measurements, Postural control tests The Clinical Test of Sensory Interaction on Balance (CTSIB) uses different conditions to test how people adapt to changing sensory conditions during the maintenance of stance. We used the modified CTSIB by NeuroCom to perform the test on a computerized force plate to measure the body sway. Static postural stability \[displacement of Centre of Pressure (CoP)\] was measured during standing on a single force platform (Stabilometer, ZWE-PII) for 20-s periods in a quiet room. Signals were amplified and sampled at 16 Hz via an analogue-to-digital converter. Subjects stood barefoot on the platform, with the feet positioned side by side and arms hanging freely at their side. Toe-out was positioned to subjects' comfort. The CoP excursions along antero-posterior (AP) and medio-lateral (ML) axes were performed both on firm (the stable surface of the platform) and foam surfaces \[an Airex Balance Pad (dimensions: 50 cm length x 41 cm width x 6 cm height) placed on the platform\], always starting with standing on the stable surface. In each condition, subjects had to stand first with the eyes open (EO), when subjects had to look at a target fixed at eye level at a distance of approximately 1 m, and then measurements were also performed with closed eyes (EC).

Conditions

Interventions

TypeNameDescription
DIAGNOSTIC_TESTPosturography measurementsDetermination of functional status, Posturography measurements, postural tests

Timeline

Start date
2015-01-01
Primary completion
2018-12-18
Completion
2018-12-18
First posted
2018-12-21
Last updated
2018-12-24

Locations

1 site across 1 country: Hungary

Source: ClinicalTrials.gov record NCT03783806. Inclusion in this directory is not an endorsement.