Clinical Trials Directory

Trials / Completed

CompletedNCT03780764

Changes in Pulpal Blood Flow Between Conventional and Self-ligating Fixed Orthodontic Brackets During Leveling and Alignment Stage

Changes in Pulpal Blood Flow of Teeth During Leveling and Alignment Stages of Orthodontic Treatment Using 2 Fixed Orthodontic Appliances

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
22 (actual)
Sponsor
Jordan University of Science and Technology · Academic / Other
Sex
All
Age
16 Years – 22 Years
Healthy volunteers
Accepted

Summary

\- Evaluate and compare initial changes in PBF between conventional and self-ligating fixed orthodontic brackets during leveling and alignment stage using 0.016" Nickle titanium (NiTi) and 0.016X0.022" NiTi archwires at different time intervals (20min, 24h, 72h, 1 week and 1 month) of initial arch wire placement.

Detailed description

Objectives: to evaluate and compare the initial changes in pulpal blood flow (PBF) between conventional and self-ligating fixed orthodontic brackets during leveling and alignment stage. Materials and Methods: A total of 22 patients (16 females and 6 males) aged 19± 2.53 years who presented with mild lower arch crowding were selected to participate in the study. A split mouth study design was applied for each patient. Two different fixed appliance brackets were used in the lower arch (self-ligating brackets on one side and conventional brackets on the other side of the same patients). PBF was measured for the lower right and left sides using Laser Doppler Flowmetry at different time intervals (20min, 24h, 72h, 1 week and 1 month) after the fitting of 2 alignment archwires; 0.016" NiTi and 0.016X0.022" NiTi. A repeated measures analysis of variance test and a Bonferroni post-hoc comparison test were applied to detect differences in PBF between the 2 groups.

Conditions

Interventions

TypeNameDescription
OTHERA Pre-adjusted edgewise brackets: 3M Gemini Unitek, 0.022" Roth prescription bracketsA pre-adjusted edgewise fixed appliance (3M Gemini Unitek, 0.022" Roth prescription brackets) on one side of lower arch. The standardized bonding technique was applied according to the manufacturer's instructions. Teeth alignment was initiated using round 0.016" NiTi arch wire until 0.016X0.022" NiTi was reached. The NiTi arch wires were placed into brackets slots and tied with elastomers (figure of 8).
OTHERSelf- ligating brackets: Unitek™ Gemini SL Self-Ligating Brackets, 0.022" Roth prescription bracketsSelf-ligating brackets (Unitek™ Gemini SL Self-Ligating Brackets, 0.022" Roth prescription brackets) on the other side of lower arch. The standardized bonding technique was applied according to the manufacturer's instructions. Teeth alignment was initiated using round 0.016" NiTi arch wire until 0.016X0.022" NiTi was reached. The NiTi arch wires were placed into brackets slots and held in place by bracket's gate in the self-ligating brackets side.

Timeline

Start date
2017-06-01
Primary completion
2017-12-31
Completion
2018-05-01
First posted
2018-12-19
Last updated
2018-12-20

Locations

1 site across 1 country: Jordan

Source: ClinicalTrials.gov record NCT03780764. Inclusion in this directory is not an endorsement.