Clinical Trials Directory

Trials / Completed

CompletedNCT03776747

Repeatability in Hyperpolarized 3-Helium With MRI

Repeatability in Hyperpolarized 3-Helium Magnetic Resonance Imaging

Status
Completed
Phase
Phase 4
Study type
Interventional
Enrollment
18 (actual)
Sponsor
Eric A. Hoffman · Academic / Other
Sex
All
Age
18 Years – 90 Years
Healthy volunteers
Accepted

Summary

The main purpose of this study is to assess and test the reproducibility and results of hyperpolarized 3-Helium gas as a contrast agent with Magnetic Resonance Imaging (MRI) of the lungs in healthy adult subjects.

Detailed description

New CT imaging techniques often expose the patient to higher doses of radiation. There is a great deal of concern about effects of medical radiation exposure on the general public and regulations are becoming stricter on the radiation doses that are allowed. One novel procedure that has been developed to evaluate the function and structure of the lung is the use of hyperpolarized gases with MRI scanners. We want to compare the lung imaging techniques that we have developed in our lab to a technique that uses hyperpolarized 3-Helium gas with MRI. This technique is free from radiation and less invasive than many lung imaging techniques. Hyperpolarized gas MRI is based on the introduction of spins into the lungs, allowing imaging to take place. The use of hyperpolarized 3-Helium has a few advantages: 1. it allows us to see the microstructure of the lungs through diffusion imaging (apparent diffusion coefficient) which correlates with the size of airways and alveolar space. 2. it allows us to see ventilation, or how air moves in the lungs, at a high resolution. 3. it is capable of ultra fast imaging which will help us assess gas flow patterns within the airways. and 4) the speed of depolarization lets us measure the partial pressure of oxygen and associated gas exchange mechanisms.

Conditions

Interventions

TypeNameDescription
DRUGProne hyperpolarized 3 helium gas scanHyperpolarized gas used as a contrast agent to test reproducibility of MRI of the lungs/Images done while subject is prone.
DRUGSupine hyperpolarized 3 helium gas scanHyperpolarized gas used as a contrast agent to test reproducibility of MRI of the lungs/Images done while subject is supine.
DIAGNOSTIC_TESTVitals
DIAGNOSTIC_TESTPulmonary Function TestsPre and post spirometry, diffuse lung carbon monoxide (DLCO), lung volumes
DIAGNOSTIC_TESTInitial protocol MRI scanInitial scan to determine placement

Timeline

Start date
2008-07-22
Primary completion
2012-06-01
Completion
2012-06-01
First posted
2018-12-17
Last updated
2023-11-01
Results posted
2023-11-01

Locations

1 site across 1 country: United States

Regulatory

Source: ClinicalTrials.gov record NCT03776747. Inclusion in this directory is not an endorsement.