Clinical Trials Directory

Trials / Completed

CompletedNCT03762525

Iliac Branch Device Movement During Cardiac Cycle (IBD-dynamics)

Anatomic Dynamics of the Internal Iliac Artery After Placement of Iliac Branched Devices Using ECG-gated Computer Tomography Angiography Imaging (IBD-dynamics)

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
45 (actual)
Sponsor
Rijnstate Hospital · Academic / Other
Sex
All
Age
Healthy volunteers
Not accepted

Summary

The incidence of isolated common iliac artery (CIA) aneurysms is low, but in combination with an abdominal aortic aneurysm (AAA) they are found in approximately 20-40% of cases. Basically, two different endovascular strategies can be applied to treat a CIA aneurysm with, including 1. the coverage and 2. the preservation of blood flow to the internal iliac artery (IIA). Coil and coverage of the IIA is related to ischemic complications, including buttock claudication, erectile dysfunction and the more severe spinal and colonic ischemia. Iliac branched devices (IBD) have been developed to exclude CIA aneurysms preserving the IIA and currently three alternatives are on the market. Clinical results of these devices are promising but loss of patency is not uncommon. The major difference between the two devices is the IIA component. The Cook IBD uses a -non-dedicated IIA component, while in the GORE® EXCLUDER® Iliac Branch Endoprosthesis (Gore IBE device) a dedicated self expanding stent is used. Stresses and forces exerted onto the endograft by aortic pulsatility may have an effect on the durability and functioning of the endograft. Intermittent hinchpoints could also have an effect on stent integrity and stenosis. By evaluating endograft movement during the cardiac cycle (ECG-gated CTA) it is possible to assess the stress and force exerted onto the endograft. This might help gain insight into mechanisms underlying potential endograft failure, and aid procedural planning and the development of future devices with long-term durability. The choice for device is not part of this study.

Detailed description

Objectives:To compare the mobility of the hypogastic artery during the cardiac cycle before and six weeks after implantation of the Gore IBE device in conjunction with its dedicated self expandable Internal Iliac component (Sub-study A);and to quantitatively characterize the displacement of stents with regard to the main body and native IIA during the cardiac cycle on an implanted iliac branched endograft in conjunction with a non-dedicated IIA component (Cook IBD with Advanta V12 or Fluency) with those in conjunction with a dedicated self expandable Internal Iliac component (Gore IBE device). (Sub-study B) Study design: Sub-study A \& B: Multicenter observational case studies Study population: Sub-study A: 15 prospectively included patients and sub-study B: 15 patients in each group that have been treated in the period October 2006 - July 2016.

Conditions

Interventions

TypeNameDescription
RADIATIONECG gated CTARoutine care consists of a preoperative and several postoperative CTA scans. In A. The preoperative and first postoperative CTA will be replaced by ECG-gated CTA imaging and in B. the scheduled imaging will be replaced by an ECG-gated CTA. General information: The protocol is based on the ECG gated cardiac protocol using abdominal parameter settings.

Timeline

Start date
2016-10-05
Primary completion
2020-12-31
Completion
2020-12-31
First posted
2018-12-03
Last updated
2021-02-12

Locations

3 sites across 1 country: Netherlands

Source: ClinicalTrials.gov record NCT03762525. Inclusion in this directory is not an endorsement.