Clinical Trials Directory

Trials / Completed

CompletedNCT03716557

A High Frequency Spinal Cord Stimulation PET-CT Scan Study

A Prospective Single Blind Pilot Study to Investigate the Dynamic Brain Imaging Response to Changes in Frequency Parameters in Patients With Spinal Cord Stimulation With Intractable Neuropathic Pain

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
22 (actual)
Sponsor
Barts & The London NHS Trust · Academic / Other
Sex
All
Age
18 Years – 75 Years
Healthy volunteers
Not accepted

Summary

This study aims to investigate the clinical response to Spinal Cord Stimulation frequency parameters: 40Hz, 4000Hz and 10000Hz and explore the brain imaging changes using PET-CT scans. The response to these stimulator settings on health related quality of life will also be measured using validated questionnaires.

Detailed description

Spinal cord stimulation (SCS) is a treatment option for people suffering with chronic neuropathic back and leg pain. Conventionally, patients receiving SCS are provided with tonic stimulation parameters, where the frequency of electrical pulses is set at 40-60Hz. The major side effect of tonic SCS parameters is the onset of paraesthesia, a tingling or pins and needles sensation within the target region, which can cause discomfort for some patients. However, newer methods include high-frequency stimulation (HF) which is able to provide paraesthesia free stimulation, ultimately providing better patient tolerability. HF stimulation is widely offered to patients with SCS as part of routine clinical practice. However, the effect on pathways in the brain remains to be characterised. This study therefore aims to investigate the clinical response to three frequency parameters 40Hz, 4000Hz and 10000Hz and also explore the brain imaging changes using PET-CT scans. The response to these stimulator settings on health related quality of life will also be measured using validated questionnaires. 20 patients who are deemed suitable for SCS as part of NICE guidelines 159 pathway will be recruited for the study. All patients will have a baseline PET-CT scan and undergo first stage of SCS where they will be offered tonic 40Hz settings as part of trial stimulation. If successful (\>50% improvement in pain scores) patients will be offered second stage and continue to receive 40Hz stimulation for 4 weeks. After a second PET-CT scan they are randomised to receive either 4000Hz or 10000Hz stimulation for 4 more weeks, then cross-over treatment for another 4 weeks. PET-CT scans will be performed between each level of stimulation and at the end of the study (4 in total).

Conditions

Interventions

TypeNameDescription
DEVICESpinal Cord Stimulation 4000HzDifferential programming of the Boston Scientific Precision™ Plus Spinal Cord Stimulator System
DEVICESpinal Cord Stimulation 10000HzDifferential programming of the Boston Scientific Precision™ Plus Spinal Cord Stimulator System
DEVICESpinal Cord Stimulation 40HzDifferential programming of the Boston Scientific Precision™ Plus Spinal Cord Stimulator System

Timeline

Start date
2018-02-09
Primary completion
2020-01-31
Completion
2020-01-31
First posted
2018-10-23
Last updated
2025-01-09

Locations

1 site across 1 country: United Kingdom