Safety and Efficacy Study of Abdominal Aortic Aneurysm Stent Graft System

Safety and Efficacy Study of Abdominal Aortic Aneurysm Stent Graft System for Infrarenal Abdominal Aortic Aneurysm: A Prospective, Multi-center, Objective Performance Criteria Clinical Trial

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
156 (actual)
Sponsor
Lifetech Scientific (Shenzhen) Co., Ltd. · Industry
Sex
All
Age
18 Years – 85 Years
Healthy volunteers
Not accepted

Summary

A prospective, multi-centre, objective performance criteria clinical trial to evaluate the safety and efficacy of Abdominal Aortic Aneurysm Stent Graft System manufactured by Lifetech Scientific (Shenzhen) Co., LTD. for the infrarenal abdominal aortic aneurysm.

Detailed description

This clinical trial was conducted in a qualified clinical trial institution. Investigators will use Abdominal Aortic Aneurysm Stent Graft System manufactured by Lifetech Scientific (Shenzhen) Co., LTD. to treat patients with Infrarenal Abdominal Aortic Aneurysm. This is a Prospective, Multi-center, Objective Performance Criteria Clinical Trial. It is expected to submit to the ethics committee of the lead unit for review in March 2018, and complete the implantation of 156 patients in 22 centres nationwide within 12 months, and interim follow-up was conducted before discharge, 30 days after surgery, 6 months after surgery and 12 months after surgery, long-term follow-up will be performed at 24 months postoperatively, 36 months postoperatively, 48 months postoperatively and 60 months postoperatively. This trial will evaluate whether the device reached the primary safety endpoint and primary efficacy endpoint through two primary endpoint indicators: the incidence of major adverse events (MAE) within 30 days and the success rate of abdominal aortic aneurysm treatment 12 months after surgery. This trail will evaluate whether the device reached the secondary safety endpoint and primary efficacy endpoint through several secondary endpoint indicators: Perioperative (intraoperative to postoperative 30 days) delivery related complications incidence rate (including the transabdominal surgery caused by intraoperative conveyors, the hemorrhage in the middle iliac artery, the hemorrhage in the femoral artery at the puncture site, the hematoma and the pseudoaneurysm), the incidence of acute lower limb ischemia before discharge and 30 days after surgery, all-cause mortality at 6 months, 12 months and 2-5 years after surgery, abdominal aortic aneurysm-related mortality at 6 months, 12 months and 2-5 years after surgery, the incidence of severe adverse events (SAE) at 6 months, 12 months and 2-5 years after surgery, the incidence of the device-related adverse events (AE) at 6 months, 12 months and 2-5 years after surgery, the incidence of type I or type III leakage at 6 months, 12 months after surgery, the incidence of displacement of Abdominal Aortic Aneurysm Stent at 6 months, 12 months after surgery and the incidence of conversion from abdominal aortic aneurysm treatment to open surgery or secondary surgery intervention at 6 months, 12 months and 2-5 years after surgery. According to the guidelines for clinical trials of aortic stent system, the sponsor will apply for CFDA listing registration after completing a 12-month primary endpoint assessment. According to the guidelines for clinical trials of aortic covered stent system, the sponsor will apply for CFDA listing registration after completing a 12-month primary endpoint assessment, and annually follow-up will be conducted until the fifth year for the long-term efficacy observation.

Conditions

Interventions

TypeNameDescription
DEVICEAbdominal Aortic Aneurysm Stent Graft SystemAbdominal aortic bifurcation stent and iliac artery extension stent were preloaded into abdominal aortic bifurcation stent transporter and iliac artery extension stent transporter, respectively. In the operation, the abdominal aorta bifurcation stent and the iliac artery extension stent will be delivered to the corresponding lesion position of the abdominal iliac artery and release. The abdominal aortic bifurcation stent and the iliac artery extension stent will form a whole through docking and thereby reducing the risk of rupture of an infrarenal abdominal aortic aneurysm due to the shock of blood flow.

Timeline

Start date
2018-09-30
Primary completion
2020-11-30
Completion
2025-03-31
First posted
2018-09-27
Last updated
2019-12-30

Locations

22 sites across 1 country: China