Clinical Trials Directory

Trials / Completed

CompletedNCT03645174

Long Endotracheal Tube vs. Aintree Intubating Catheter for Fiberoptic-guided Intubation in Manikin

Fiberoptic-guided Endotracheal Intubation Through Laryngeal Mask Airway in Manikin; Long Endotracheal Tube vs. Aintree Intubating Catheter

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
20 (actual)
Sponsor
Ajou University School of Medicine · Academic / Other
Sex
All
Age
20 Years – 40 Years
Healthy volunteers
Accepted

Summary

In difficult airway situation, fiberoptic-guided endotracheal intubation through laryngeal mask airway(LMA) is one of option. Aintree catheter is a device to help change LMA to endotracheal tube, but it needs complex and multiple process. Long endotracheal tube can solve this problem of Aintree catheter. The purpose of this study is proving the efficacy of long endotracheal tube compared to Aintree cathter in fiberoptic-guided intubation through LMA.

Detailed description

In difficult aiway situation, fiberoptic-guided endotracheal intubation through laryngeal mask airway(LMA) is one of option according to Difficult intubation guidelines. First, insert LMA and insert fiberoptic through LMA. Second, insert endotracheal tube using fiberoptic as a guide. This process has several problem. Removal of LMA is impossible, so there is a risk of dislodging of endotracheal tube. Aintree catheter is developed to this problem. Insert Aintree catheter through LMA using fiberoptic, and remove LMA, finally insert endotracheal tube throug Aintree catheter. But the problem of this method is that the whole process is complex and takes long time. And there is a risk of impeding of endotracheal tube at glottis level because the difference of diameters between endotracheal tube and aintree catheter. Long endotracheal tube could solve the problems mentioned above. Through LMA, insert endotracheal tube using fiberoptic as a guide. Tube is long enough to remove LMA without a risk of dislodging. And after removal of LMA, tube can be cut for optimizing length. So the purpose of this study is comparing the efficacy of Aintree catheter method and Long tube method in manikin.

Conditions

Interventions

TypeNameDescription
DEVICEUsing long tubeFiberoptic-guided intubation through LMA, using long tube
DEVICEAintree catheterFiberoptic-guided intubation through LMA, using Aintree catheter

Timeline

Start date
2018-09-01
Primary completion
2018-12-31
Completion
2019-01-15
First posted
2018-08-24
Last updated
2019-03-07

Locations

1 site across 1 country: South Korea

Source: ClinicalTrials.gov record NCT03645174. Inclusion in this directory is not an endorsement.