Trials / Completed
CompletedNCT03632577
High Flow Oxygen VERSUS Non Invasive Ventilation Associated to Automated Flow Oxygen Titration After Patient Extubation
High Flow Oxygen (HFO) VERSUS Non Invasive Ventilation (NIV) Associated to Automated Flow Oxygen Titration (AFOT) After Extubation in Patient With Respiratory Risk: Non-inferiority Prospective Comparative Study
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 55 (actual)
- Sponsor
- University Hospital, Toulouse · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
Extubation stay at high risk of reintubation even scheduled and in the best condition of hematosis. Re-intubation's rate in main studies in chronic obstructive diseases reach to 20% and it is associated to a higher mortality, higher pneumonia under mechanic ventilation, and higher duration of hospitalization especially in intensive care units. Place of NIV in this situation is still on evaluation. A recent meta-analysis demonstrates that use of NIV in post-extubation in COPD seems to decrease re-intubation rate. HFO, thanks to its properties (oxygen, humidification and heat with high flow) could be useful in this population in ventilatory weaning. Compared to oxygen conventional therapy with high-concentration mask, HFO seems to be as efficient and better tolerated. A recent study shows that HFO is non-inferior to NVI in post-extubation in patient with high risk of re-intubation. Furthermore, oxygenation in post-extubation should be optimized to avoid hypoxemia and hypercapnia in this patient at risk of hypoventilation. Place of AFOT could improve hematosis by providing adapted flow of oxygen to each patient. The investigator choose the hypothesis for this study that HFO is as effective and tolerated in post-extubation than NIV with AFOT.
Detailed description
A recent meta-analysis demonstrates that use of NIV in post-extubation in obstructive chronic bronchopathies seems to decrease re-intubation rate. High Flow Oxygen, thanks to its properties (oxygen, humidification and heat with high flow) could be useful in this population in ventilatory weaning. Compared to oxygen conventional therapy with high-concentration mask, High Flow Oxygen seems to be as efficient and better tolerated . A recent study shows that High Flow Oxygen is non-inferior to Non Invasive Ventilation in post-extubation in patient with high risk of re-intubation. Furthermore, oxygenation in post-extubation should be optimized to avoid hypoxemia and hypercapnia in this patient at risk of hypoventilation.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | High Flow Oxygen (HFO) | HFO is a mix tap of air and oxygen. It permits to control FiO2 and generated controlled high flow air until 60/min. Air and oxygen are mixed, warmed, humidified and issued to patient by a warming monopod inspiratory circuit to nasal cannulas of a large diameter. Expiration is free. |
| DEVICE | Non Invasive Ventilation (NIV) | NIV was already evaluated in post-extubation. This technic is now used in daily consolidation processing after extubation because it provides a ventilator help with two levels of pressure helping in respiratory work. Adding Automated Flow Oxygen Titration could optimized patient's oxygenation and reduce workload of caregivers. |
Timeline
- Start date
- 2017-12-19
- Primary completion
- 2019-06-26
- Completion
- 2019-10-15
- First posted
- 2018-08-15
- Last updated
- 2020-11-10
Locations
1 site across 1 country: France
Source: ClinicalTrials.gov record NCT03632577. Inclusion in this directory is not an endorsement.