Clinical Trials Directory

Trials / Completed

CompletedNCT03622099

Small Volume Fluid Challenge as a Predictor of Fluid Responsiveness in Patients With Circulatory Failure

Transthoracic Echocardiography Guided Small Volume Fluid Challenge as a Predictor of Fluid Responsiveness in Patients With Circulatory Failure: An Observational Study

Status
Completed
Phase
Study type
Observational
Enrollment
54 (actual)
Sponsor
Menoufia University · Academic / Other
Sex
All
Age
18 Years – 60 Years
Healthy volunteers
Not accepted

Summary

Assessment of intravascular volume status is difficult in critically ill patients. Evidence suggests that only 50% of hemodynamically unstable patients respond to a fluid challenge. Moreover, if cardiopulmonary function cannot compensate for the increase in preload, fluid loading may compromise microvascular perfusion and oxygen delivery and cause or aggravate peripheral and pulmonary edema. Inappropriate fluid expansion can increase morbidity and mortality thus making it important to accurately assess fluid responsiveness in critically ill patients. The volume responsiveness can be defined as a 15% increase in stroke volume (SV) or cardiac output (CO) after a 500-ml infusion. This study tested whether echocardiographic parameters can predict fluid responsiveness in critically ill patients following a low volume 100-ml crystalloid solution infusion over 1 minute.

Detailed description

Fifty-four adult patients with circulatory failure were recruited for the study. As a routine work in adult critical care unit at Menoufia University hospital for patients with circulatory failure, a 100 ml bolus of normal saline solution was given to the patient over 1 minute through a central venous catheter or jugular cannula. For prediction of responders, echocardiographic parameters were recorded1 minute after bolus administration. The remaining 400 ml of normal saline solution was infused at a constant rate over 10 minutes, and echocardiographic parameters were recorded again. The mean echocardiographic measurements over three consecutive respiratory cycles were recorded along with heart rate HR, systolic, diastolic and mean arterial pressures, central venous pressure, and Temperature also mechanical ventilation parameter (tidal volume, respiratory rate and PEEP) for each patient. Patients with an increase in CO after a 100 ml or total 500-ml infusion over 10 minutes (ΔCO500) of 15% or more were classified as responders (Rs) and those without an increase in CO was classified as non-responders

Conditions

Interventions

TypeNameDescription
DRUGNormal Saline Flush, 0.9% Injectable SolutionAs a routine work in adult critical care unit at Menoufia University hospital for patients with circulatory failure, A 100 ml bolus of Normal Saline Flush, 0.9% Injectable Solution was given to the patient over 1 minute through a central venous catheter or jugular cannula. For prediction of responders, echocardiographic parameters measured followed by infusion of the remaining 400 ml of Normal Saline Flush, 0.9% Injectable Solution at a constant rate over 10 minutes then echocardiographic parameters measured again to detect the patient response.

Timeline

Start date
2018-09-07
Primary completion
2019-02-05
Completion
2019-02-26
First posted
2018-08-09
Last updated
2019-04-25

Locations

1 site across 1 country: Egypt

Source: ClinicalTrials.gov record NCT03622099. Inclusion in this directory is not an endorsement.