Clinical Trials Directory

Trials / Unknown

UnknownNCT03621709

CoreValve™ Evolut R™ 34 mm System Registry (CoreValve34)

Multicenter Ambispective Study of Clinical Outcomes of the CoreValve™Evolut R™ 34mm System: All Comers Post-market Registry

Status
Unknown
Phase
Study type
Observational
Enrollment
100 (estimated)
Sponsor
Fundacin Biomedica Galicia Sur · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

With the introduction of the CoreValve™ Evolut R™ 34mm (Medtronic™) prosthesis, patients with severe symptomatic aortic stenosis (AS) and large aortic annulus have become eligible for transcatheter aortic valve implantation (TAVI). The aim of this study is to detect the number of TAVI candidates with large aortic annulus, and to evaluate the feasibility, efficacy, and safety of TAVI using the CoreValve™ Evolut R™ 34mm.

Detailed description

With the current transcatheter valves available in the market, is possible to cover a wide range of patients with diverse and complex anatomies. Nevertheless, there is a subgroup of patient with large aortic annulus (diameter \> 27 mm), in whom the implant of a transcatheter valve is not possible because there is no valve suitable for such as aortic annulus size. With the introduction of the CoreValveTM EvolutionTM R 34mm, patients with an aorttic annulus dimension up to 29 mm in diameter have become eligible for TAVI. However, there is a lack of information regarding the number of patient with AS and this particular anatomy of the aortic annulus. Italian and Dutch registries have reported a prevalence between 6.5 to 12.3% with large aortic annulus requiring the previous CoreValveTM 31mm. Yet, there is no reported data regarding this population of patients in Spain. Also, the clinical use of this larger prosthesis covers a wider range of aortic rings and may enchance the procedural challenges, such as a little margin for proper valve placement, more likelihood of interference with mitral valve function and damage to the cardiac conduction system during the prosthesis deployment. So far, no studies regarding clinical experiences with the CoreValveTM EvolutionTM R 34mm have been published. The scarce information currently available with this new device may be distant from those found in its daily clinical use in non-selected patients. The results of this Spanish nationwide registry will help to answer a scientific need of information regarding acute procedural results and mid

Conditions

Timeline

Start date
2017-08-01
Primary completion
2020-07-01
Completion
2020-09-01
First posted
2018-08-08
Last updated
2020-03-19

Locations

1 site across 1 country: Spain

Source: ClinicalTrials.gov record NCT03621709. Inclusion in this directory is not an endorsement.