Clinical Trials Directory

Trials / Unknown

UnknownNCT03608891

Patient Specific Plates Versus Conventional Miniplates for Treatment of Mandibular Body Fractures

Patient Specific Three-Dimensional Titanium Plates Versus Conventional Miniplates for Treatment of Mandibular Body Fractures. (Randomized Clinical Trial)

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
20 (estimated)
Sponsor
Cairo University · Academic / Other
Sex
All
Age
18 Years – 60 Years
Healthy volunteers
Accepted

Summary

The aim of the current study is to evaluate and assess the clinical stability and efficacy of patient specific computer guided titanium plates versus the conventional titanium mini plates regarding accurate reduction and fixation of mandibular body fractures, reducing the operating time, achieving precise bone alignment and reducing the plate palpability.

Detailed description

The study will be conducted on two groups: Intervention group: patient specific three-dimensional titanium plates CBCT or CT scan will be performed for the patient, the dicom files will be imported into a surgical planning software , plates will then be designed virtually and sent for three-dimensional (3D) printing. Control group: Conventional miniplates: In this group two miniplates of titanium Mini-System 2.0 mm will be used. The plate has profile height 1.0 mm whereas the screw length varies according to the site of the plate. According to Champy osteosynthesis lines for fixation of the posterior mandibular fracture ,the first plate will be placed at the inferior border from the buccal side, using bicortical screws engaging the buccal and lingual cortices to achieve rigid fixation, while the second plate will be placed at about 5mm superior to the inferior plate in the subapical region, using monocortical screws engaging only the buccal cortex to avoid injuring the teeth roots.

Conditions

Interventions

TypeNameDescription
DEVICEComputer guided patient specific 3D titanium plateCBCT or CT scan will be done preoperatively and dicom files will be imported to mimics software to design and print the patient specific 3D titanium plate.
DEVICEConventional titanium miniplatesIn this group two miniplates of titanium Mini-System 2.0 mm will be used. The plate has profile height 1.0 mm whereas the screw length varies according to the site of the plate. According to Champy osteosynthesis lines for fixation of the posterior mandibular fracture ,the first plate will be placed at the inferior border from the buccal side, using bicortical screws engaging the buccal and lingual cortices to achieve rigid fixation, while the second plate will be placed at about 5mm superior to the inferior plate in the subapical region, using monocortical screws engaging only the buccal cortex to avoid injuring the teeth roots.

Timeline

Start date
2018-07-01
Primary completion
2019-02-01
Completion
2019-07-01
First posted
2018-08-01
Last updated
2018-08-01

Source: ClinicalTrials.gov record NCT03608891. Inclusion in this directory is not an endorsement.