Clinical Trials Directory

Trials / Unknown

UnknownNCT03586271

Comparison of the Visual Performance After Implantation of Multifocal Lens

Comparison of the Visual Performance After Implantation of a Trifocal Intraocular Lens(AT Lisa Tri 839MP) and Two Bifocal Intraocular Lenses(ReSTOR +2.5/+ 3.0D and Diff-aay)

Status
Unknown
Phase
Study type
Observational
Enrollment
60 (estimated)
Sponsor
Aier School of Ophthalmology, Central South University · Academic / Other
Sex
All
Age
40 Years – 90 Years
Healthy volunteers
Not accepted

Summary

This is a prospective, consecutive, nonrandomized,comparative study. Comparison of the Visual Performance After Implantation of a Trifocal Intraocular Lens and Two Bifocal Intraocular Lenses

Detailed description

Multifocal intraocular lenses were introduced in the 1980s and have the benefit of promoting near and far vision simultaneous. However, these multifocal lenses have the disadvantages, including lower contrast sensitivity(CS) and visual discomfort, such as halos, glares and starburst, et al. Therefore, careful patient selection is crucial to achieve good postoperative results. The purpose of this study was to compare the visual outcomes and subjective visual quality between bifocal intraocular Lens(ReSTOR +2.5/+ 3.0D and Diff-aay) and trifocal intraocular Lens(AT Lisa tri 839MP). This prospective, nonrandomized, consecutive, comparative study included the assessment of 60 patients implanted with multifocal intraocular lens. visual acuity was tested in all cases. Ophthalmological evaluation included the measurement of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), and uncorrected intermediate visual acuity (UIVA), the analysis of contrast sensitivity (CS), visual defocus curve, spectacle independence, patient satisfaction, residual sphere, spherical equivalent (SE), cylinder and complications.

Conditions

Interventions

TypeNameDescription
PROCEDUREtrifocal lensphacoemusification + trifocal lens(AT Lisa tri 839MP) implantation
PROCEDUREbifocal lens 1phacoemusification +bifocal lens(Diff-aay) implantation
PROCEDUREbifocal lens 2phacoemusification +bifocal lens (ReSTOR +3.0D) implantation
PROCEDUREbifocal lens 3phacoemusification +bifocal lens (ReSTOR +2.5D) implantation

Timeline

Start date
2018-08-02
Primary completion
2019-01-01
Completion
2019-02-01
First posted
2018-07-13
Last updated
2018-07-13

Locations

1 site across 1 country: China

Source: ClinicalTrials.gov record NCT03586271. Inclusion in this directory is not an endorsement.