Clinical Trials Directory

Trials / Unknown

UnknownNCT03578848

Guiding Hypertension Management Using Different Blood Pressure Monitoring Strategies

A Randomized Controlled Trial Comparing Unattended Automated Office Blood Pressure vs. Home Blood Pressure vs. Central Blood Pressure Monitoring for the Management of Hypertension

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
252 (estimated)
Sponsor
Taipei Veterans General Hospital, Taiwan · Other Government
Sex
All
Age
20 Years – 90 Years
Healthy volunteers
Not accepted

Summary

Patients with uncontrolled or newly diagnosed hypertension will be randomized to have hypertension management decisions made on the basis of the unattended automated blood pressure (uAOBP) , home BP, and central BP monitoring. This study evaluates the optimal guiding strategy for hypertension will help define which BP monitoring is the most effective strategy to guide the clinical management of hypertension.

Detailed description

The traditional BP used for clinical practice, the office BP, is usually measured in a busy and hurry clinical environment, and interfered by the well-known confounding whitecoat effect. As such, unattended automated office BP monitoring (uAOBP) has been proposed as an effective solution and further promoted by Canadian physicians. Nonetheless, out-of-office BP, home BP and ambulatory BP, remains the methodology of recommendation for the detection of whitecoat effect, and its prognostic value has been demonstrated to be superior to the traditional office BP. Home BP monitoring, with its ability to detect morning and masked hypertension and a better tolerability than ambulatory BP monitoring for long-term use, can therefore be considered as a strategy of choice to replace office BP monitoring for guiding hypertension management. Moreover, BP measurements in the peripheral arteries cannot serve as direct substitutes for their central counterparts because of the long-recognized differences of blood pressure (BP) waveforms and values between the central aorta and peripheral arterial system. Thus, if the decisions on medication adjustment are made solely based brachial BP, there could be a considerable risk of over- or undertreatment. Considering that there are many better strategies for guiding hypertension management than traditional office BP, there is an apparent need for investigating their comparative effectiveness and safety in the management of hypertension. The investigators hypothesized that home BP may be non-inferior to AOBP and central BP-guided intervention in reducing ambulatory BP and designed the present randomized controlled trial.

Conditions

Interventions

TypeNameDescription
DEVICEuAOBPFor the uAOBP and CBP, the measurements will be conducted in a quiet room without the presence of clinical personnel. Patients will be seated in a quiet room without talking and taken as an average of 3 measurements with an automated device (HEM-907, Omron Healthcare, Lake Forest, IL) that has been preset to wait 5 minutes before measurements. Simultaneously, the central BP will be measured in the other upper arm. (WatchBP Office Central; Microlife AG, Widnau, Switzerland). The determination of the right or left upper arm for uAOBP or central BP will be made in a random order by computer generated random codes before the enrollment.
DEVICEHome BPAs for the home BP measurements, a validated device (WatchBP Home; Microlife AG, Widnau, Switzerland) will be provided for all subjects allocated to the home BP arm to measure their BP at home. Subjects are requested to take BP in the morning (within 2 hours after awakening) and afternoon before meals for 7 consecutive days before the scheduled clinical visits. BP in the first day of the measurements will be discarded and an average of home BP (all BP reading and BP in the morning and in the afternoon) will be generated and provided for clinicians to guide their treatment.
DEVICECBPFor the uAOBP and CBP, the measurements will be conducted in a quiet room without the presence of clinical personnel. Patients will be seated in a quiet room without talking and taken as an average of 3 measurements with an automated device (HEM-907, Omron Healthcare, Lake Forest, IL) that has been preset to wait 5 minutes before measurements. Simultaneously, the central BP will be measured in the other upper arm. (WatchBP Office Central; Microlife AG, Widnau, Switzerland). The determination of the right or left upper arm for uAOBP or central BP will be made in a random order by computer generated random codes before the enrollment.

Timeline

Start date
2018-06-06
Primary completion
2019-06-01
Completion
2020-03-01
First posted
2018-07-06
Last updated
2018-09-17

Locations

1 site across 1 country: Taiwan

Source: ClinicalTrials.gov record NCT03578848. Inclusion in this directory is not an endorsement.