Summary

The aim of our study is to estimate the efficacy, safety and postoperative complications of the thulium fiber laser enucleation of the prostate (ThuFLEP) with Urolase system (NTO IRE-POLUS, Russia).

Detailed description

In all patients, IPSS, Qmax, QoL, prostate volume, and IIEF-5 are measured prior to surgery. For ThuFLEP, we use the Urolase system (NTO IRE-POLUS, Russia) and a 600 mcm fiber. The thulium fiber laser is set with a mean output power of 60 W and energy of 1.5 J. Tissue morcellation is completed with the Piranha Morcellator (Richard Wolf, Germany). At the end of the procedure a 22 French three-way Foley catheter is placed. IPSS, Qmax, QoL, prostate volume are recorded at 1, 3 and 6 months after surgery. IIEF-5 are recorded at 3 and 6 months after surgery.

Conditions

Interventions

TypeNameDescription
PROCEDUREThulium Fiber Laser Enucleation of the ProstateThulium laser enucleation of the prostate is performed using the two-lobe or en-bloc techniques. Incision depth is limited to the circular fibers of the prostate capsule. The left lobe is enucleated first, starting at the 5 o'clock position. The endoscope is then introduced counterclockwise at the 2 o'clock position. Next, an incision is made at 12 o'clock and extended to the level of the verumontanum. The incisions at the 12 and 2 o'clock positions are connected, and the left lobe is enucleated into the bladder. The right lobe of the gland is enucleated in a similar manner: the initial incision at 7 o'clock was made clockwise, an 11 o'clock incision is then extended along the capsule to join with the previous cut. The final step is morcellation of hyperplastic nodes.
DEVICEThulium Fiber Laser "Urolase"Urolase system (NTO IRE-POLUS, Russian Federation) is a thulium doped fiber laser. Max. power of 120 W and energy of 8 J. Wavelength - 1,94 µm, incision depth - 0,2 mm.

Timeline

Start date
2018-03-01
Primary completion
2021-07-01
Completion
2021-09-01
First posted
2018-06-12
Last updated
2021-07-22