Trials / Completed
CompletedNCT03537469
Neuromodulation With Low Frequency-Pulsed Electromagnetic Fields
Modulation of Long-Term Potentiation-Like Cortical Plasticity in the Healthy Brain With Low Frequency-Pulsed Electromagnetic Fields
- Status
- Completed
- Phase
- EARLY_Phase 1
- Study type
- Interventional
- Enrollment
- 10 (actual)
- Sponsor
- Azienda Socio Sanitaria Territoriale degli Spedali Civili di Brescia · Academic / Other
- Sex
- All
- Age
- 18 Years – 35 Years
- Healthy volunteers
- Accepted
Summary
Non-depolarizing magnetic fields, like Low Frequency-Pulsed Electromagnetic Fields (LF-PEMFs) have shown the ability to modulate living structures, principally by influencing synaptic activity and ion channels on cellular membranes. Recently, the CTU Mega 20 device was presented as a molecular accelerator, using energy up to 200 Joules and providing high-power (2 Tesla) pulsating fields with a water-repulsive (diamagnetic) action and tissue biostimulation. The investigators tested the hypothesis that LF-PEMFs could modulate long-term corticospinal excitability in healthy brains by applying CTU Mega 20®. Ten healthy subjects without known neurological and/or psychiatric diseases entered the study. A randomized double-blind sham-controlled crossover design was employed, recording TMS parameters (amplitude variation of the motor evoked potential as index of cortical excitability perturbations of the motor system) before (pre) and after (post +0, +15, +30 min) a single CTU Mega 20 session on the corresponding primary right-hand motor area, using a real (magnetic field = 2 Tesla; intensity = 90 J; impulse frequency = 7Hz; duration = 15 minutes) or sham device. A two-way repeated measures ANOVA with TIME (pre, post +0, +15, +30 min) and TREATMENT (real vs sham stimulation) as within-subjects factor was applied.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | CTU Mega 20 real device | The CTU Mega 20 diamagnetic acceleration system discharges high-field magnetic impulses (with a duration of 5 ms and a period of 1000 ms), generating a magnetic field up to 2 Tesla, with a frequency of 7500 Hz in a volume of approximately 27 cm3. |
| DEVICE | CTU Mega 20 sham device | A CTU Mega 20 sham device (with an identical appearance to that of the real device) to avoid treatment identification by the patient or experimenter was used. Of course, the application of this sham device did not provide any magnetic field. |
Timeline
- Start date
- 2016-03-10
- Primary completion
- 2016-07-01
- Completion
- 2016-07-10
- First posted
- 2018-05-25
- Last updated
- 2018-05-29
Source: ClinicalTrials.gov record NCT03537469. Inclusion in this directory is not an endorsement.