Clinical Trials Directory

Trials / Unknown

UnknownNCT03528590

Ventilation Efficacy of Size 3 or Size 4 I-gel in Female Patient Weighing 50 to 60 Kilograms

Ventilation Efficacy of I-gel® Size 3 and Size 4 Supraglottic Airway Devices in Anesthetized, Paralyzed Female Patients Weighing Between 50 and 60 Kilograms: a Randomized Trial

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
98 (estimated)
Sponsor
National Taiwan University Hospital · Academic / Other
Sex
Female
Age
20 Years
Healthy volunteers
Not accepted

Summary

Currently, the main method for selecting an i-gel® size is based on the body weight recommendation (30-60 kg for size 3 and 50-90 kg for size 4) according to the manufacturer's recommendation. However, there is an overlapping in size selection in people weighing between 50 and 60 kilograms. Laryngeal mask airways are widely used for breast surgery, and this patient cohort is often weighed between 50-60 kilograms in National Taiwan University Hospital. Therefore, in this randomized clinical trial, the investigators will compare the ventilation efficacy of size 3 and size 4 i-gel® in anesthetized, paralyzed female patients weighing 50 to 60 kilograms who undergo breast surgery. Also, the investigators will record any side effects of size 3 and size 4 i-gel® in this cohort.

Detailed description

With the introduction of the laryngeal mask, it has been widely used for the management of airway during general anesthesia. Compared to the endotracheal tube, it has the advantages of easier and faster placing, reducing the proportion of a sore throat and other benefits. The i-gel® is a second-generation of the laryngeal mask. Compared to the classic laryngeal mask, it provides higher sealing pressure and better airway protection to reduce respiratory complications. Choosing an appropriate size laryngeal mask is an important issue. Trauma during placing or positive ventilation failure may occur if the wrong size is selected. Currently, the main method for selecting an i-gel® size is based on the body weight recommendation (30-60 kg for size 3 and 50-90 kg for size 4) according to the manufacturer's recommendation. However, there is an overlapping in size selection in people weighing between 50 and 60 kilograms. Laryngeal mask airways are widely used for breast surgery, and this patient cohort is often weighed between 50-60 kilograms in National Taiwan University Hospital. Therefore, in this randomized clinical trial, the investigators will compare the ventilation efficacy of size 3 and size 4 i-gel® in anesthetized, paralyzed female patients weighing 50 to 60 kilograms who undergo breast surgery. Also, the investigators will record any side effects of size 3 and size 4 i-gel® in this cohort. Keywords: Airway management; laryngeal mask airway; breast surgery

Conditions

Interventions

TypeNameDescription
DEVICEsize 3 i-gel supraglottic airway deviceUse size 3 i-gel® in anesthetized, paralyzed female patients weighing 50 to 60 kilograms who undergo breast surgery.
DEVICEsize 4 i-gel supraglottic airway deviceUse size 4 i-gel® in anesthetized, paralyzed female patients weighing 50 to 60 kilograms who undergo breast surgery.

Timeline

Start date
2018-05-28
Primary completion
2019-03-01
Completion
2019-05-01
First posted
2018-05-18
Last updated
2018-05-30

Locations

1 site across 1 country: Taiwan

Source: ClinicalTrials.gov record NCT03528590. Inclusion in this directory is not an endorsement.

Ventilation Efficacy of Size 3 or Size 4 I-gel in Female Patient Weighing 50 to 60 Kilograms (NCT03528590) · Clinical Trials Directory