Clinical Trials Directory

Trials / Completed

CompletedNCT03461029

Bispectral Index Monitoring During Anesthesiologist - Directed Sedation in Scheduled Colonoscopies

Status
Completed
Phase
Study type
Observational
Enrollment
196 (actual)
Sponsor
Hospital Galdakao-Usansolo · Other Government
Sex
All
Age
18 Years – 80 Years
Healthy volunteers
Accepted

Summary

The aim of the study is to establish and identify the level of sedation that is performed in the endoscopy rooms of Galdakao Hospital. To do this, the investigators used the BIS monitoring system, which obtains objective values in real time from the anesthesia performed. The monitoring is completed with basic parameters validated by European guidelines (heart rate, blood pressure, oxygen saturation and respiratory rate), capnography and Ramsay sedation scale, widely validated for use outside the operating room. The main work hypothesis was that in at least 10% of the patients BIS values compatible with moderate or deep sedation would be obtained (BIS \<65).

Detailed description

Observational study in patients undergoing scheduled colonoscopy in endoscopy rooms of the Galdakao-Usansolo Hospital. The investigators objectified the level of sedation that was performed in these procedures using Bispectral Index Monitoring, as well as the total dose of medication required and the level of satisfaction obtained after completing the sedation. The incidence of hemodynamic and respiratory complications observed was included, as well as the treatment needed to solve them. A total of 196 patients were needed to obtain statistically significant results. Qualitative variables are expressed in the form of freguencies and percentages and continuous variables in the form of means and stnadard deviations. Comparisions of percentages were made by the Chi square test and the difference of means in the continuous variables by the t test.Stadistical significance will be assumed when p\<0.05. All estadistical analyzes were carried out using SAS V9.4 (SAS Institute, Inc., Carey, NC).

Conditions

Interventions

TypeNameDescription
DEVICEBIS monitorThe investigators placed on the forehead of all patients the sensor BIS quatroTM, that connects with the monitor, and they registered sedation and recorded the values obtained.

Timeline

Start date
2016-01-30
Primary completion
2017-12-30
Completion
2018-02-20
First posted
2018-03-09
Last updated
2018-03-09

Locations

1 site across 1 country: Spain

Source: ClinicalTrials.gov record NCT03461029. Inclusion in this directory is not an endorsement.