Clinical Trials Directory

Trials / Completed

CompletedNCT03455738

Dynamic Arterial Elastance Measured by Uncalibrated Pulse Contour Analysis Predicts Arterial Pressure Response to a Decrease in Norepinephrine

Dynamic Arterial Elastance Measured by Uncalibrated Pulse Contour Analysis Predicts Arterial Pressure Response to a Decrease in Norepinephrine (VESA) Dynamic Arterial Elastance Measured by Uncalibrated Pulse Contour Analysis

Status
Completed
Phase
Study type
Observational
Enrollment
35 (actual)
Sponsor
Centre Hospitalier Universitaire, Amiens · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers

Summary

Dynamic arterial elastance (Eadyn) has been proposed as an indicator of arterial tone that can predict norepinephrine-dependent arterial pressure. Eadyn is calculated using the ratio of respiratory pulse pressure variation (PPV) over the respiratory stroke volume variation (SVV). Guinot et al demonstrated a decrease in the duration of norepinephrine treatment with the use of Eadyn. To date, studies that have validated Eadyn at bedside have used cardiac output (CO) calibrated pulse contour analysis (PiCCO™, Pulsion™) or oesophageal doppler. Such monitoring systems need dedicated and specific arterial line and venous access that may limit their use at bedside. In addition to CO calibrated pulse contour analysis, CO uncalibrated pulse contour analysis has been developed and is considered less invasive. Nevertheless, one limitation of the latter CO monitoring is inaccuracy of CO measurement in patients who are being treated with norepinephrine. These limitations may affect the predictability of Eadyn. We conducted a prospective study in a university hospital ICU. Patients with vasoplegic syndrome for whom the intensive care physician planned to decrease the norepinephrine dosage were included. Hemodynamic and uncalibrated pulse contour analysis (Volume view, FloTrac, Edwards Lifescience, Irvine) values were obtained before and after decreasing the norepinephrine dosage. Responders were defined by a \>10% decrease in mean arterial pressure (MAP).

Detailed description

* Background : Dynamic arterial elastance (Eadyn) has been proposed as an indicator of arterial tone that can predict norepinephrine-dependent arterial pressure. Eadyn is calculated using the ratio of respiratory pulse pressure variation (PPV) over the respiratory stroke volume variation (SVV). Guinot et al demonstrated a decrease in the duration of norepinephrine treatment with the use of Eadyn. To date, studies that have validated Eadyn at bedside have used cardiac output (CO) calibrated pulse contour analysis (PiCCO™, Pulsion™) or oesophageal doppler. Such monitoring systems need dedicated and specific arterial line and venous access that may limit their use at bedside. In addition to CO calibrated pulse contour analysis, CO uncalibrated pulse contour analysis has been developed and is considered less invasive. Nevertheless, one limitation of the latter CO monitoring is inaccuracy of CO measurement in patients who are being treated with norepinephrine. These limitations may affect the predictability of Eadyn. * Purpose : To date, no study has evaluated the ability of Eadyn measured by uncalibrated pulse contour analysis to assess arterial pressure response to a decreased dose of norepinephrine. We tested the hypothesis that Eadyn calculated from uncalibrated pulse contour analysis predicts the arterial-pressure response to a norepinephrine decrease in patients treated with norepinephrine

Conditions

Interventions

TypeNameDescription
OTHERvasoplegic syndromePatients with vasoplegic syndrome for whom the intensive care physician planned to decrease the norepinephrine dosage were included. Hemodynamic and uncalibrated pulse contour analysis (Volume view, FloTrac, Edwards Lifescience, Irvine) values were obtained before and after decreasing the norepineprhine dosage. Responders were defined by a \>10% decrease in mean arterial pressure (MAP).

Timeline

Start date
2016-10-11
Primary completion
2017-04-26
Completion
2017-04-26
First posted
2018-03-07
Last updated
2018-09-28

Source: ClinicalTrials.gov record NCT03455738. Inclusion in this directory is not an endorsement.