Clinical Trials Directory

Trials / Unknown

UnknownNCT03443466

Efficacy and Safety of Electric Stimulation-guided Epidural Anesthesia for Cesarean Section

A Comparative Study of Success Rate, Efficacy, Safety Between Electric Stimulation-guided Epidural Catheter Placement and the Loss of Resistance Conventional Method for Cesarean Section

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
40 (estimated)
Sponsor
Korea University Guro Hospital · Academic / Other
Sex
Female
Age
19 Years – 64 Years
Healthy volunteers
Not accepted

Summary

Forty pregnant women (36 to 41 weeks gestation) will randomly allocate to two groups. Groups will be defined based on the method used to identify the epidural space for epidural anesthesia: the loss of resistance group (n=20) and the epidural electric stimulation group (n=20). Pain during the cesarean section will be assessed using a numerical visual analog scale and maternal satisfaction by a post-partum interview. The success rate of epidural anesthesia, maternal satisfaction, and neonatal Apgar scores will be compared between groups.

Detailed description

Investigators will place epidural catheter in the epidural space using loss of resistance technique, and will confirm correct placement of the epidural catheter using electric stimulation. Epidural catheter placement, electric stimulation, and confirmation of response is followed: Patients will be placed in the left lateral decubitus position. The site will be aseptically prepared and 1% lidocaine will be infiltrated to the skin. An 18-gauge Tuohy needle will be inserted midline of L4/5 interspinous space. For the LOR group, after identification of the epidural space, the Tuohy needle will be stopped, and a 20-gauge epidural catheter will be advanced through the Touhy needle. The same process will be followed for the EES group. In addition, the epidural space will be confirmed by epidural electric stimulation using a 20-gauge epidural catheter (RegionalStimTm, Sewoon Medical Co., Ltd, Seoul, Korea, 800 mm) with a conductive guidewire (conductive guidewire, Nitinol, 1100 mm). After confirming there is no reverse flow of cerebrospinal fluid or blood with aspiration, 3 mL of 1% lidocaine, with 15 mcg of epinephrine (1:200000), will be injected through the epidural catheter as test dose. If there is no response to the test dose, patients will be moved to the operating room. In operating room, 20 mL of 2% lidocaine, 2 mL of bicarbonate (total volume 22 mL) will be administered in divided doses. Blood pressure (BP), heart rate (HR), oxygen saturation (SpO2), and neurologic assessment findings will be monitored. Pain relief in cesarean section is assessed in the visual analogue scale (VAS) score. A 10 point VAS, where 0 is no pain and 10 is unbearable pain, is used to assess pain during labor. The scale is assessed after epidural anesthesia. Differences in the VAS we used to assess the efficacy of the epidural anesthesia in decreasing labor pain. Comparison of the change in VAS between groups is used to compare pain control of the two methods. The success of epidural anesthesia is defined by sensory block, without motor block, and a decrease in pain score after adequate dosing of epidural medication. Failure of epidural anesthesia is defined in several ways. Objective outcome include conversion to general anesthesia, conversion to any different form of anesthesia, or pain during surgery. Patient satisfaction will be evaluated by a postpartum interview. Satisfaction is graded between a score of 1-5, where 1 represent very unsatisfied and 5 represent very satisfied. Patients will indicate a score of 1 to 5. One- and 5-minute Apgar scores will be compared to assess the effect of epidural electric stimulation on the neonate. Additional time required for epidural electric stimulation will be determined by the difference (in seconds) from LOR to identification of the epidural space through electric stimulation.

Conditions

Interventions

TypeNameDescription
DEVICEEpidural electrical stimulation (EES)Using loss of resistance technique and electrical stimulation
DEVICELoss of resistance (LOR)Using loss of resistance technique only

Timeline

Start date
2015-03-11
Primary completion
2019-03-01
Completion
2019-03-01
First posted
2018-02-23
Last updated
2018-02-23

Locations

1 site across 1 country: South Korea

Source: ClinicalTrials.gov record NCT03443466. Inclusion in this directory is not an endorsement.

Efficacy and Safety of Electric Stimulation-guided Epidural Anesthesia for Cesarean Section (NCT03443466) · Clinical Trials Directory