Trials / Unknown
UnknownNCT03439176
Investigating the Adhesion of New Adhesive to the Skin
A Pilot Evaluation Exploring New Adhesive Materials and Their Ability to Handle Moisture From Abdominal and Peristomal Skin
- Status
- Unknown
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 6 (actual)
- Sponsor
- Coloplast A/S · Industry
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Accepted
Summary
The adhesion of the new adhesive strips is investigated on healthy volunteers
Detailed description
Inclusion visit: * Introduction to the study * Inclusion in study * Baseline information is obtained * Instruct subject to pre-strip of abdominal skin Test visits 1-25 (up to maximum 25 visits per subject. (1-3 days after pre-stripping the abdominal skin): * Baseline measurements are conducted on both sides of the stomach (TEWL, hydration, erythema, pH - 3 repeated measurements under each adhesive strip area (upper, middle and bottom of adhesive strip) * Potential wetting of skin - shower/bicycle exercise (max 60 minutes) and after-wetting baseline measurements are conducted (TEWL, hydration, erythema, pH - 3 times/strips (upper, middle and bottom of adhesive strip)) * Adhesive strips are weighted and applied * Potential shower/bicycle exercise (max 60 minutes) * Adhesive strips are removed at pre-defined timeslots (peel force measured) * Discomfort when strip was peeled of is evaluated by subject (VAS) * Measurements are conducted (TEWL, hydration, erythema, pH - 3 times/strips (upper, middle and bottom of adhesive strip)) * Acclimatization ½ * Measurements are conducted (TEWL, hydration, erythema, pH - 3 times/strips (upper, middle and bottom of adhesive strip)) * Adhesive strips are weighed * Photo of adhesive strips The subjects can be asked to apply and change strips every 24 hours between two test visits but for a maximum of 10 days between two visits. The strips should be applied at the same place every time.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| OTHER | Standard adhesive 1 | This strip contains a standard hydrocolloid adhesive found in ostomy devices |
| OTHER | Standard adhesive 2 | This strip contains a standard hydrocolloid adhesive found in ostomy devices |
| OTHER | PL4 | This strip contains a new adhesive |
| OTHER | PL16-L | This strip contains a new adhesive |
Timeline
- Start date
- 2018-01-15
- Primary completion
- 2018-02-15
- Completion
- 2020-06-30
- First posted
- 2018-02-20
- Last updated
- 2020-01-27
Locations
1 site across 1 country: Denmark
Source: ClinicalTrials.gov record NCT03439176. Inclusion in this directory is not an endorsement.