Clinical Trials Directory

Trials / Unknown

UnknownNCT03439176

Investigating the Adhesion of New Adhesive to the Skin

A Pilot Evaluation Exploring New Adhesive Materials and Their Ability to Handle Moisture From Abdominal and Peristomal Skin

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
6 (actual)
Sponsor
Coloplast A/S · Industry
Sex
All
Age
18 Years
Healthy volunteers
Accepted

Summary

The adhesion of the new adhesive strips is investigated on healthy volunteers

Detailed description

Inclusion visit: * Introduction to the study * Inclusion in study * Baseline information is obtained * Instruct subject to pre-strip of abdominal skin Test visits 1-25 (up to maximum 25 visits per subject. (1-3 days after pre-stripping the abdominal skin): * Baseline measurements are conducted on both sides of the stomach (TEWL, hydration, erythema, pH - 3 repeated measurements under each adhesive strip area (upper, middle and bottom of adhesive strip) * Potential wetting of skin - shower/bicycle exercise (max 60 minutes) and after-wetting baseline measurements are conducted (TEWL, hydration, erythema, pH - 3 times/strips (upper, middle and bottom of adhesive strip)) * Adhesive strips are weighted and applied * Potential shower/bicycle exercise (max 60 minutes) * Adhesive strips are removed at pre-defined timeslots (peel force measured) * Discomfort when strip was peeled of is evaluated by subject (VAS) * Measurements are conducted (TEWL, hydration, erythema, pH - 3 times/strips (upper, middle and bottom of adhesive strip)) * Acclimatization ½ * Measurements are conducted (TEWL, hydration, erythema, pH - 3 times/strips (upper, middle and bottom of adhesive strip)) * Adhesive strips are weighed * Photo of adhesive strips The subjects can be asked to apply and change strips every 24 hours between two test visits but for a maximum of 10 days between two visits. The strips should be applied at the same place every time.

Conditions

Interventions

TypeNameDescription
OTHERStandard adhesive 1This strip contains a standard hydrocolloid adhesive found in ostomy devices
OTHERStandard adhesive 2This strip contains a standard hydrocolloid adhesive found in ostomy devices
OTHERPL4This strip contains a new adhesive
OTHERPL16-LThis strip contains a new adhesive

Timeline

Start date
2018-01-15
Primary completion
2018-02-15
Completion
2020-06-30
First posted
2018-02-20
Last updated
2020-01-27

Locations

1 site across 1 country: Denmark

Source: ClinicalTrials.gov record NCT03439176. Inclusion in this directory is not an endorsement.