Accuvein Versus Standard Care for Intravenous Cannulation Procedure in Children

Peripheral Intravenous Cannulation in Children With Difficult Vein Access : Randomized Study Comparing Accuvein®400 Versus Standard Care

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
300 (estimated)
Sponsor
University Hospital, Clermont-Ferrand · Academic / Other
Sex
All
Age
1 Day – 3 Years
Healthy volunteers
Not accepted

Summary

Peripheral intravenous cannulation is one of the most common procedures performed in children admitted to hospital. It is a painful and anxiety-provoking gesture for children with possible memorization of the pain even more present for patients with chronic pathology. Nevertheless, this care is essential to administer the treatments. The cannulation is usually set up by the observation and touching of the veins by the nurse. However, this technique is often insufficient in young children and especially infants because they have a higher thickness adipose tissue. Their veins are of small caliber, hardly visible and palpable which increases the probability of a failure of the insertion of the catheter at the first attempt. In the literature, different techniques are mentioned to promote the visualization of veins and thus the insertion of cannulation. The AccuVein®400 (AV400) system uses an infrared laser beam to project the image of superficial veins to the skin. In adults, AV400 has been shown to improve the success rate of insertion cannulation when venous capital is precarious. The question now arises as to whether this tool could be of interest to children who are particularly difficult to assist cannulation, especially the youngest of them. Investigator hypothesize that AV400 could bring a benefit to the placement of cannulation, in the child with a venous capital difficult to catheterize and thus increase the success of the cannulation at the first attempt.

Detailed description

Children admitted to pediatric emergencies, pediatric day hospitals and the general pediatric ward, who are less than 3 years old and whose care requires the placement of a cannulation will be identified by the caregivers as potentially included. The DIVA score will be carried out by the nurse who takes care of the child thanks to the dedicated form. If the child has an Emla® patch, this score will be achieved after removing the patch. The nurse that will achieve the score will be the same that will pose the intravenous cannulation. Children with an assessment score \<4 will not be included in the study but will still be counted. The nurse must perform the randomization by inquiring about the randomization week: standard method or AV400 method. The information will be made to the parents and the information form given. The parents' consent regarding the care of their child will be collected by the same nurse. The means of prevention of pain and distraction will be set up in box with the nurse and / or the auxiliary childcare and the parents. Peripheral intravenous cannulation will be performed by the nurse in collaboration with the auxiliary childcare. Caregivers and parents will evaluate the care. The documents concerning the practical realization of the study will be grouped together and made available in each service in dedicated bins.

Conditions

Interventions

TypeNameDescription
DEVICEAccuvein®400The intervention comes down to the randomization of the standard treatment versus Accuvein for peripheral intravenous cannulation
OTHERStandard careThe intervention comes down to the randomization of the standard treatment versus Accuvein for peripheral intravenous cannulation