Trials / Unknown
UnknownNCT03382197
Different Positive Pressure Strategies in COPD Patients.
Regional Ventilation and Radioaerosol Pulmonary Deposition Through Different Positive Pressure Strategies in COPD Patients.
- Status
- Unknown
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 10 (estimated)
- Sponsor
- Universidade Federal de Pernambuco · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
Chronic obstructive pulmonary disease (COPD) is characterized by a poorly reversible airway obstruction and consequent systemic manifestations. Its high prevalence and high number of diagnosed patients has become a challenge for health services due to the costs of diagnosis and treatment of these patients. Positive pressure and aerosol therapy are preferred therapies for the management of COPD symptoms, but their effects when associated are poorly studied. The objective of this study is to compare the effects of different positive pressure strategies associated with aerosol therapy through Pulmonary Scintigraphy and Electrical Impedance Tomography (EIT) in patients with COPD in the intercrise period. This is a randomized, crossover, blinded and allocated crossover type clinical trial in which patients with moderate to severe COPD will be allocated to three intervention groups with different strategies for positive pressure associated with aerosol therapy: control group 1 nebulization), group 2 nebulization with EPAP valve and group 3 nebulization with NIV bi-level pressure mode. The radioaerosol deposition pattern will be evaluated through Pulmonary Scintigraphy and regional pulmonary ventilation through EIT.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | Nebulization | For inhalation of the radioaerosol a dose of DTPA-Tc99m (methionine-labeled diethylnitriaminepentaacetic acid) with 1mCi activity, associated with 10 drops of Fenoterol Bromide and 20 drops of Ipatropium Bromide diluted for a total of up to 3 ml of saline solution 0.9%. A MESH vibrating nebulizer (NIVO, Philips Respironics, Murrysville, Pennsylvania) will be used. |
| DEVICE | Positive expiratory pressure valve | For nebulization associated with the EPAP valve will be used a non-invasive distribution system consisting of a non-toxic orofacial mask connected to a spring loaded EPAP valve. This mask will be secured to the patient's face through tabs in order to prevent leakage and to maintain proper pressurizing and better patient adaptation. |
| DEVICE | Nonivasive ventilation | For nebulization associated with NIV, a noninvasive distribution system consisting of a non-toxic orofacial mask connected to the NIV circuit will be used, and the latter will be being fed by a radioaerosol flow generated by a nebulizer coupled to the circuit. This mask will be secured to the patient's face through tabs in order to prevent leakage and to maintain proper pressurizing and better patient adaptation. |
Timeline
- Start date
- 2018-01-01
- Primary completion
- 2018-03-16
- Completion
- 2018-11-01
- First posted
- 2017-12-22
- Last updated
- 2018-07-31
Locations
1 site across 1 country: Brazil
Source: ClinicalTrials.gov record NCT03382197. Inclusion in this directory is not an endorsement.