Air Leakage Under Continuous Positive Airway Pressure

Retrospective Analysis of the Determinants of Air Leakage in a Population of Obstructive Sleep Apnea Syndrome Treated With Continuous Positive Airway Pressure

Status
Completed
Phase
Study type
Observational
Enrollment
79 (actual)
Sponsor
University Hospital, Montpellier · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

The software embedded in recent continuous positive pressure devices enables the analysis of the level of leakage that occurs during treatment around the mask or from the mouth. However, there is no clear threshold defining when it would be appropriate to implement means for correcting these leaks. In addition, the calculation methods used to detect/measure leaks and the terminology used vary according to the manufacturers of continuous pressure devices, which also complicates the clinical interpretation of the leakage reports provided by the various devices. In daily practice, when a patient complains of unintentional leakage, technicians adjust the mask, replace the nasal-mask by an oro-nasal mask or install a chinstrap. Nevertheless, those strategies are not always effective in reducing leakage or patient's complaints. A better understanding of the mechanisms beyond leak appearance for a given patient could lead to individualised leak-treatment solutions. Pressure level, mandibular behaviour, respiratory effort, sleep position or sleep stages may contribute to leak emergence. A recent exploratory study has proposed a genuine analysis method of determining factors of unintentional-leaks using polysomnographic recordings in OSA patients treated with automatic Continuous Positive Airway Pressure (auto-CPAP). Based on the same methodology, the NOMICS company (Liège, Belgium) has developed a polygraphic device (Brizzy®) recording unintentional leakage during auto-CPAP treatment and providing an etiological analysis of unintentional-leaks via a software named APIOS. Due to the innovative nature of the analysis, it appears necessary to validate it onto a population of OSA patients treated with auto-CPAP. Also, to our knowledge, there is no descriptive data of the distribution of the determinants of unintentional leaks in such a population. From this perspective, the investigators aim to retrospectively analyse some polygraphic recordings that have been performed with the Brizzy® on OSA patients treated with auto-CPAP. The primary objective of this study is to identify and describe the determinants of unintentional leaks for a population of patients with OSA and treated with an auto-CPAP device

Detailed description

The secondary objectives are: 1. to evaluate the concordance of the determinants of leaks according to different leak thresholds (0 l/min ; 5l/min ; 10l/min : 20l/min). 2. to describe any technical problems that arise in relation to the analysis of leaks in the study population.

Conditions

Interventions

TypeNameDescription
DEVICEBrizzy continuous positive pressure devicePatients are treated with the Brizzy continuous positive pressure device, including pneumotachograph.

Timeline

Start date
2018-01-10
Primary completion
2018-04-20
Completion
2018-04-20
First posted
2017-12-22
Last updated
2020-07-02

Locations

3 sites across 1 country: France

Source: ClinicalTrials.gov record NCT03381508. Inclusion in this directory is not an endorsement.