WithdrawnNCT03378492

Utilizing Ultrasound for Residents as an Aid in Epidural Placement

Status
Withdrawn
Phase
N/A
Study type
Interventional
Enrollment
0 (actual)
Sponsor
Yale University · Academic / Other
Sex
Female
Age
18 Years – 45 Years
Healthy volunteers
Accepted

Summary

This randomized controlled trial will evaluate the use of ultrasound as an aid for epidural placement in residents performing all epidural techniques under direct staff anesthesiologist supervision.

Detailed description

The purpose of this study is to assess the abilities of the "Accuro" to assist in lumbar epidural placement in patients. It is hypothesized that the use of the Accuro will result in an increase of first-attempt success rates, defined as successful epidural needle placement on the first needle insertion attempt.

Conditions

Interventions

TypeNameDescription
DEVICEUltrasound Guided EpiduralSterile ultrasound gel will be applied to the patient's back and the sterile device will be used to image the lumbar vertebrae in the area of the palpation-derived location. When the device is placed above the vertebral interspace, the 3D image mode will identify the spine midline and the depth from the skin to the epidural space. A single 3D ultrasound video loop of the vertebral interspace will be saved to confirm correct landmark identification. After identification of the vertebral interspace, the skin will be marked with a marking utensil or physical indentation at the point of needle entry indicated by the device. The epidural needle will then be placed in the same fashion as in the standard procedure group. The depth of the epidural needle placement will be measured and recorded following observation of loss of resistance.
PROCEDUREStandard EpiduralThe point of needle entry will be located using the landmarks technique. The specific level of epidural placement will be determined on a per-patient basis at the anesthesiologist's discretion. The spine midline will also be palpated to determine the approximate location of an interlaminar space. The needle will then be inserted at the appropriate location determined by the landmarks technique, and successful epidural placement will be confirmed by observation of loss of resistance and follow-up confirmation of analgesia. The depth of the epidural needle placement will be measured and recorded following observation of loss of resistance. The epidural catheter will be inserted and the procedure will continue according to the standard of care.

Timeline

Start date
2018-08-01
Primary completion
2019-11-01
Completion
2020-11-01
First posted
2017-12-19
Last updated
2019-01-10

Regulatory

Source: ClinicalTrials.gov record NCT03378492. Inclusion in this directory is not an endorsement.