Study of the Choroidal and Retinal Thickness in Relation to Axial Length.
Study of the Choroidal and Retinal Thickness in Relation to Axial Length in Healthy Young Subjects With Swept-source Optical Coherence Tomography.
- Status
- Completed
- Phase
- —
- Study type
- Observational
- Enrollment
- 55 (actual)
- Sponsor
- Semmelweis University · Academic / Other
- Sex
- All
- Age
- 18 Years – 29 Years
- Healthy volunteers
- Accepted
Summary
The aim of the study is the non-invasive morphological evaluation of the choroid and the retina in relation to the length of the eyeball in healthy, young man and women.
Detailed description
The choroid is responsible for the oxygen supply of the outer retina, hence many diseases that affect the retina are originating from the choroid or at later stages influence the choroid as well. The functional efficiency of the choroid in a healthy subject is important. The thickness of the choroid is a marker for the extent of the vessels inside. With optical coherence tomography (OCT) non-invasive and non-contact measurement of the choroidal and retinal thickness is possible. Swept-source OCT is one the latest developments of OCTs. Its increase wavelength allows deeper penetration than previous models and allows high resolution imaging. OCTs are FDA approved machines, they are not considered experimental. The swept-source OCT machine (DRI OCT-1 Model Triton (plus), Topcon, Tokyo, Japan) used in the study is a CE marked commercially available medical device. The goal of the study is to evaluate the choroidal and the retinal morphology in relation to the length of the eyeball (axial length - AL) in healthy, young adults. There are several publications on this topic, most of them on asian populations. In the study healthy, Caucasians in their twenties are recruited to minimize the aging effect on choroidal thickness. Following informed consent, demographics are recorded, refraction is taken, axial length is measured with IOL Master 500 (Carl Zeiss AG, Germany) then OCT is performed. Pupil dilation is not necessary. Images are stored digitally by abiding corresponding laws on personal data protection. Results are processed with statistical analysis.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | AL measurement | IOL Master 500 (Carl Zeiss AG, Germany) |
| DEVICE | OCT | Choroidal and retinal thickness measurement (DRI OCT-1 Model Triton (plus), Topcon, Tokyo, Japan) |
Timeline
- Start date
- 2017-02-06
- Primary completion
- 2018-10-03
- Completion
- 2018-11-30
- First posted
- 2017-12-19
- Last updated
- 2019-02-27
Locations
1 site across 1 country: Hungary
Regulatory
- FDA-regulated device study
Source: ClinicalTrials.gov record NCT03377075. Inclusion in this directory is not an endorsement.