A Prospective Randomized Controlled Trial of Dual-Mobility Components in Primary THA

A Prospective Randomized Trial of Modular Dual Mobility Acetabular Components Versus Conventional Single Bearing Components in Primary Total Hip Arthroplasty

Status
Active Not Recruiting
Phase
Phase 4
Study type
Interventional
Enrollment
52 (estimated)
Sponsor
Rush University Medical Center · Academic / Other
Sex
All
Age
18 Years – 80 Years
Healthy volunteers
Not accepted

Summary

The aim of this study is to determine if the use of a modular dual mobility bearing is associated with clinically important increases in serum metal levels.

Detailed description

Prosthetic dislocation following total hip arthroplasty (THA) remains a significant concern with a reported incidence of 0.2%-7.0% after primary and 10%-25% after revision THA. The risk of dislocation following THA is multifactorial and includes both surgeon-related factors (i.e. component positioning, surgical approach) and patient-related factors (i.e. gender, age). Dual mobility articulations have been shown to reduce the incidence of hip instability following THA. Dual mobility implants have been used in Europe for over 30 years, but have recently received an increased interest in the United States. Initial dual mobility designs consisted of a cementless, monoblock acetabular component with a highly-polished metal inner bearing surface. Modular dual mobility prostheses have been introduced in which a modular cobalt-alloy liner is inserted into a hemispherical titanium acetabular component. Advantages of this construct include familiarity of use of a standard titanium acetabular component and the ability to use supplemental screw fixation. However, the potential for fretting corrosion between the cobalt-alloy liner and the titanium acetabular component remains a concern. In a retrospective review of 100 consecutive patients undergoing primary THA using a modular dual mobility prosthesis, the authors found 21% of patients to have a serum cobalt level above the normal range, with 9% significantly above normal (\> 1.6 ug/L), at a mean of 27.6 months postoperatively. In addition, a recent prospective cohort study of 26 patients receiving the same prosthesis showed elevated whole blood mean cobalt levels in patients receiving a modular dual mobility prosthesis versus patients receiving a conventional bearing (0.23 + 0.39 vs. 0.15 + 0.07ug/L, p\<0.001) at 1 year postoperatively. Four patients in the dual mobility cohort had a whole blood cobalt level outside the reference range (maximum 1.81 ug/L). To the investigators knowledge no prospective, randomized controlled trial has been performed comparing dual mobility bearings to a conventional single-bearing design. Therefore, the purpose of this study is to compare the use of a conventional single-bearing ceramic-on-polyethylene surface to use of a modular dual mobility bearing in a prospective, randomized controlled setting.

Conditions

Interventions

TypeNameDescription
DEVICEDual mobility cohortPatients will receive the Taperloc femoral stem, ceramic femoral head (size 32mm for acetabular components 48/50mm; size 36mm for acetabular components \> 52mm), polyethylene bearing, and G7 acetabular shell.
DEVICEConventional cohortPatients will receive a Taperloc femoral stem, ceramic femoral head (size 32mm for acetabular components 48/50mm; size 36mm for acetabular components \> 52mm), polyethylene bearing, and G7 acetabular shell

Timeline

Start date
2017-12-15
Primary completion
2035-12-01
Completion
2036-12-01
First posted
2017-12-13
Last updated
2026-01-08