Clinical Trials Directory

Trials / Completed

CompletedNCT03370016

The Impact of Low Pressure Pneumo in RARP

The Impact of Low Pressure Pneumoperitoneum in Robotic Assisted Radical Prostatectomy: A Prospective Randomized Controlled Trial

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
222 (actual)
Sponsor
Metro Health, Michigan · Academic / Other
Sex
Male
Age
40 Years
Healthy volunteers
Not accepted

Summary

The purpose of this study is to evaluate clinical significance of low pressure pneumoperitoneum during robotically assisted radical prostatectomy (RARP).

Detailed description

Laparoscopic and robotic surgery has revolutionized post-operative outcomes across surgical specialties. However, the use of pneumoperitoneum comes with known risks given the change in physiological parameters that accompany its utilization. The effects of increased intra-abdominal pressure on cardiopulmonary function has been well documented. Increased pressure on the large vessels may lead to decreased cardiac output and thereby decreased blood flow to various organ systems and cause irreversible damage. Some studies have advocated lower pressures to further optimize cardiopulmonary parameters. McDougall, et. al, for instance, demonstrated a significant reduction in oliguria when pressures of 10mm Hg were used. The purpose of this study is to evaluate the effect of using lower pressure pneumoperitoneum in the abdominal cavity during RARP. The investigators hypothesize that low pressure pneumoperitoneum has a multitude of clinical benefits due to improved physiologic parameters including a reduction in the occurrence of post-operative ileus, reduced need for narcotics post operatively, and a decrease in cardiopulmonary complications. The study is a prospective randomized blinded cohort study. Patients who meet eligibility criteria will be randomly assigned to undergo RARP at a pneumoperitoneum pressure of 12mm Hg or 8mm Hg. This will be done by computer generated randomization protocol. Surgeon and patients will be blinded to the pneumoperitoneum pressure used. A cover will be placed over the AirSeal™ system so that the surgeon(s) are not able to visualize the pneumoperitoneum used during the procedure. The remainder of the procedure will be carried out based on current standard of care. All patients will be admitted post operatively and the same standardized order-set in EPIC EHR will be used for all patients in order to control for other factors, such as opioid use, to control for confounders.

Conditions

Interventions

TypeNameDescription
PROCEDUREAmount of Pneumoperitoneum Pressure applied during RARPPatients will be randomly assigned to undergo RARP either at a pneumoperitoneum pressure of 8 mmHg (experimental) or 12mm Hg (standard technique)

Timeline

Start date
2017-10-17
Primary completion
2020-03-10
Completion
2020-06-30
First posted
2017-12-12
Last updated
2023-10-12

Locations

1 site across 1 country: United States