CompletedNCT03355274

Systematic Transcutaneous Oxymetry Use in Thoracic Outlet Syndrome

Application de l'oxymétrie Dynamique Pour le Diagnostic Des Syndromes de défilés Thoraco-brachiaux Systematic Transcutaneous Oxymetry Use in Thoracic Outlet Syndrom

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
222 (actual)
Sponsor
University Hospital, Angers · Other Government
Sex
All
Age
18 Years
Healthy volunteers
Accepted

Summary

The measurement of the transcutaneous oxygen partial pressure (TCPO2) at exercise is, to our knowledge, the only method to estimate during the exercise the importance of ischemia segment of limb by segment of limb bilaterally and carry on. The diagnosis of thoracic outlet syndrome causing remains difficult and dependent operator in ultrasound because of the risk of false positive (loss of signal) or false negative (insufficient effort, inappropriate movement). Our main hypothesis is the existence of significant measurable ischemia in the forearm by transcutaneous oximetry during the maneuvering of the "candlestick". In the event of failure of this maneuver, the other maneuvers such as those of Wright, Roos, Tinel and Adson will be realized. In this study we want to evaluate the possibility of using dynamic transcutaneous Oximetry as a tool for evaluating ischemia in case of suspicion of thoracic outlet syndrome causing.

Detailed description

Patients referred for suspected thoracic outlet syndrome causing and healthy asymptomatic subjects will be included. After signing the consent, the subject will have a clinical and paraclinical examination. Age, sex, height, weight, side of clinical symptomatology will be collected. Medical history current treatments will also be noted. The examination of transcutaneous oximetry dynamic measurement with palmar face of both forearms during two consecutive maneuvers known as the "candlestick" (hands up). The most symptomatic arm value in patients and the dominant arm in the control group will be noted. In case of DROP between 0 and -25 mmHg, in addition to the maneuvering of the "candlestick", the other maneuvers such as those of Wright, Roos, Tinel and Adson will be realized. The results of any additional examinations and / or pre- and post-operative consultations will be collected. Subjects complete two Quality of Life questionnaires: the SF-12 (Short Form 12) and the DASH questionnaire (Disabilities of the Arm, Shoulder and Hand). Added by an amendment : Photoplethysmography has already done its proofs to determine the thoracic outlet syndrome diagnotic. Combine with a camera Kinect, they should determine the angle of appearance of compression in the 3 dimensions of space.

Conditions

Interventions

TypeNameDescription
DIAGNOSTIC_TESTTranscutaneous OximetryThe examination of transcutaneous Oximetry dynamic measurement with palmar face of both forearms during two consecutive maneuvers known as the "candlestick" (hands up).
DIAGNOSTIC_TESTPhotopletysmographyManeuvers are repeted with the photoplestysmography sensors and in front of a Kinect camera.
OTHERQuestionnaires of Quality of Life (QoL)Each subject complete 2 QoL questionnaires : Sf-12 (Short Form 12) and DASH (Disabilities of the Arm, Shoulder and Hand).

Timeline

Start date
2018-03-26
Primary completion
2024-01-04
Completion
2024-01-04
First posted
2017-11-28
Last updated
2025-03-17

Locations

1 site across 1 country: France