Clinical Trials Directory

Trials / Completed

CompletedNCT03264599

Measurement of the Fetal Occiput-spine Angle During the First Stage of Labor as Predictor of the Outcome of Labor

Measurement of the Fetal Occiput-spine Angle During the First Stage of Labor as Predictor of the Maternal and Fetal Outcome of Labor

Status
Completed
Phase
Study type
Observational
Enrollment
400 (actual)
Sponsor
Cairo University · Academic / Other
Sex
Female
Age
18 Years – 35 Years
Healthy volunteers

Summary

2D trans abdominal ultrasound was done during the first stage of labor. If fetal position is occiput anterior and fetal presentation is vertex, two dimensional sagittal picture of the fetal head and upper spine was acquired and stored in the ultrasound machine. On this image, the offline measurement of the angle formed by a line tangential to the occipital bone and a line tangential to the first vertebral body of the cervical spine (occiput-spine angle) will be performed to quantify the degree of fetal head flexion in respect to the trunk

Detailed description

2D trans abdominal ultrasound was done during the first stage of labor. If fetal position is occiput anterior and fetal presentation is vertex, two dimensional sagittal picture of the fetal head and upper spine was acquired and stored in the ultrasound machine. On this image, the offline measurement of the angle formed by a line tangential to the occipital bone and a line tangential to the first vertebral body of the cervical spine (occiput-spine angle) will be performed to quantify the degree of fetal head flexion in respect to the trunk. The sonographer was not involved in the patient's care and the managing obstetrician was blinded to the ultrasound findings and the occiput-spine angle. For each patient of the study group, the progress of labor using a partogram ( cervical dilation ,effacement ,consistency, position and station ) and the mode of delivery were assessed retrospectively.

Conditions

Interventions

TypeNameDescription
DEVICEtransabdominal ultrasound2D trans abdominal ultrasound was done during the first stage of labor. If fetal position is occiput anterior and fetal presentation is vertex, two dimensional sagittal picture of the fetal head and upper spine was acquired and stored in the ultrasound machine. On this image, the offline measurement of the angle formed by a line tangential to the occipital bone and a line tangential to the first vertebral body of the cervical spine (occiput-spine angle) will be performed to quantify the degree of fetal head flexion in respect to the trunk

Timeline

Start date
2016-07-11
Primary completion
2017-07-21
Completion
2017-08-20
First posted
2017-08-29
Last updated
2017-08-29

Locations

1 site across 1 country: Egypt

Source: ClinicalTrials.gov record NCT03264599. Inclusion in this directory is not an endorsement.