Clinical Trials Directory

Trials / Unknown

UnknownNCT03226535

Ultrasound-CT Fusion System for Interventional Radiology Procedures

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
20 (estimated)
Sponsor
Clear Guide Medical · Industry
Sex
All
Age
18 Years – 85 Years
Healthy volunteers
Not accepted

Summary

The objective of this research is to use the Clear Guide SCENERGY technology, an FDA approved Ultrasound-CT fusion imaging system, that allows the user to fuse CT images onto a real-time ultrasound that is being performed on the patient. This fusion system will be used to perform ultrasound guided needle placements for patients undergoing percutaneous CT guided needle-based intervention. This study will consist of 20 patients, 10 patients using the CGM SCENERGY US-CT system and 10 patients using guidance only. The primary goal of the study is to prove that the new imaging fusion system is comparable to using either CT or US guidance alone to guide needle placement.

Detailed description

A simple 20 patient study will be performed using the CG SCENERGY system. This fusion system will be used to perform image guided needle placements for patients undergoing percutaneous CT guided needle-based intervention (CT guided biopsy, CT guided drain placement within the abdomen or pelvis, and CT guided injection of muscle or nerve within the pelvis). Only patients who are already scheduled for a CT guided procedure will be screened. The study design is as follows: * 10 patients will have their procedure performed using the CGM SCENERGY US-CT fusion system and 10 patients will have their procedure performed using CT guidance only. * Proper informed consent will be obtained * Perform a CT scan with the optical adhesive skin markers in place. Markers are placed around the expected site of needle skin entry. * The first 10 patients Group#1 (1-10) will be assigned to using the SCENERGY fusion system to complete the needle placement, and the next 10 patients Group #2 (11-20) will be assigned of continuing with CT guidance only to complete the needle placement. * If in Group #1, the procedure will proceed as usual using the SCENERGY system to guide the needle to target. If in the Group #2, CT guidance will be used to place the needle to target. * Once the needle is at the target, a confirmatory CT will be performed. * If the target is reached (i.e., the software directed the interventional radiologist to the right place, e.g. for correctly biopsying a lesion), the trial is considered a "success" and the procedure continues as normal. * If the needle is not in the right place, the trial is considered a "failure", and the procedure continues as normal without using the CGM software any further.

Conditions

Interventions

TypeNameDescription
DEVICEUltrasound-CT FusionThe Clear Guide SCENERGY is an Ultrasound-CT fusion device which supplements existing ultrasound and CT capabilities. The participants randomly selected (out of 20 patients) for use of the Clear Guide SCENERGY (test group) will receive ultrasound-CT fusion guidance from the MDs performing the procedure.

Timeline

Start date
2017-06-22
Primary completion
2018-06-22
Completion
2018-06-22
First posted
2017-07-21
Last updated
2017-07-21

Locations

1 site across 1 country: United States

Regulatory

Source: ClinicalTrials.gov record NCT03226535. Inclusion in this directory is not an endorsement.