Continuous Non-invasive Assessment of Blood Pressure in Bariatric Surgery

Continuous Non-invasive Assessment of Blood Pressure in Comparison to the Invasive Gold-standard and to the Sphygmomanometer.

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
50 (actual)
Sponsor
University Hospital Schleswig-Holstein · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

Comparability of discontinuous non-invasive (sphygomanometric) and continuous semi-invasive and invasive (Masimo© ; Nexfin© Monitoring ; FloTrac© Edwards Lifesciences) beat to beat measurement methods for the determination of arterial blood pressure in patients undergoing bariatric surgery.

Detailed description

Comparison between non-invasive discontinuous blood pressure measurement using a sphygomanometric blood pressure cuff, and continuous non-invasive and invasive beat to beat blood pressure measurement methods(Nexfin© and FloTrac©). Bariatric patients show limitations regarding the conventional monitoring options with ECG derivation, pulse oxymetric oxygen saturation and sphygmomanometric blood pressure measurement. From a clinical point of view this results in an invasive arterial blood pressure monitoring . In addition to that, intraoperative extreme changes of the patients position on the table combined with the applied pneumoperitoneum during the minimally invasive laparoscopic surgery can significantly influence the cardiovascular parameters. An invasive arterial blood pressure monitoring is able to reproduce the blood pressure by stroke, but it does not give any information about the cardiac output. The sphygmomanometric blood pressure measurement also entails the risk of insufficient detection of a hypotonic phase in the measurement. Additional monitoring systems are currently available, which are capable of measuring completely non-invasive or semi-invasively different cardiovascular parameters such as cardiac output (CO) and fluid responsiveness. In this study, the investigators will compare continuous and discontinuous cardiovascular monitoring procedures and their parameters. The measurements take place at specific times, under defined changes in the body position with the additional influence of the pneumoperitoneum. These changes are recorded and compared at the same time during different measuring methods preoperatively, intraoperatively and postoperatively. The non-invasive Nexfin© Monitoring (Edwards Lifesciences) is to be evaluated and compared with further measurement methods (FloTrac© (Edwards Lifesciences)) as well as the sphygmomanometric upper arm blood pressure measurement. The investigators also compare the non-invasive and invasive continuous beat to beat blood pressure measurement with conventional, discontinuous sphygomanometric upper arm blood pressure measurement. The planned study is the comparison of 3 different hemodynamic monitoring procedures. For the evaluation the investigators use the method described by Bland and Altmann for calculating the mean deviation (bias) and the precision (mean value ± 2 standard deviations. In the case of multiple measurements , the modification of the Bland-Altman method is applied (repeated measurements). The number of cases was determined with n = 60 patients, followed by an intermediate evaluation. For a Bland-Altman analysis, the width w of the confidence interval for the Limits of Agreement is calculated as w = 6.79 • σ • 1 / √n, where n is number of cases and σ is the standard deviation. For a case count of n = 60, the result is w = 0.88 • σ and thus for this explorative study a sufficiently large number. In case of the dynamic variables, the percentage matching and the calculation of the kappa index are also used for the statistical evaluation.

Conditions

Interventions

TypeNameDescription
PROCEDUREbaseline alert 1measurement in supine position
PROCEDUREAnti-Trendelenburg-position (ATB)measurement under ATB
PROCEDUREATB in narcosismeasurement under ATB in narcosis
PROCEDUREbaseline in narcosis 1measurement in supine position in narcosis
PROCEDUREpassive leg raisingmeasurement under passive leg raising
PROCEDUREvolume bolus substitutionmeasurement in supine position after volume bolus (15 ml/kgKG Sterofundin balanced solution intravenous)
PROCEDUREbaseline in narcosis 2measurement in supine position
PROCEDUREstart capnoperitoneummeasurement in supine position
PROCEDUREATB plus capnoperitoneummeasurement under ATB plus capnoperitoneum
PROCEDUREATB plus capnoperitoneum plus volume bolus substitutionmeasurement in ATB plus capnoperitoneum after volume bolus (15 ml/kgKG Sterofundin balanced solution intravenous)
PROCEDUREATB loss of capnoperitoneummeasurement under ATB
PROCEDUREbaselinemeasurement in supine position
PROCEDUREbaseline alert 2measurement in supine position
PROCEDUREtorso position rising 30° at the beginningmeasurement in the recovery unit
PROCEDUREtorso position rising 30° at the endmeasurement in the recovery unit

Timeline

Start date
2015-06-01
Primary completion
2017-06-01
Completion
2017-06-01
First posted
2017-06-12
Last updated
2017-06-12

Locations

1 site across 1 country: Germany