Comparative Study of Baska & I-gel for Ventilation of Female Patients During Minor Procedures
Comparative Study of Baska & I-Gel for Spontaneously Ventilated Females During Minor Gynecological Procedures
- Status
- Unknown
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 60 (actual)
- Sponsor
- Cairo University · Academic / Other
- Sex
- Female
- Age
- 18 Years – 55 Years
- Healthy volunteers
- Not accepted
Summary
The study aimed to compare safety of the 3rd generation Supra-glottic airway device (SAD) "Baska" to the I-Gel , regarding seal pressure, fitting on the larynx (detected by Fiberoptic) \& complications. The study will be done for females undergoing minor gynecological procedures under general anesthesia with spontaneous ventilation.
Detailed description
Population of study \& disease condition : 2 equal groups (n=30), female patients enrolled for minor gynecological procedures (D\&C or hysteroscopy), All patients received general anesthesia with spontaneous ventilation using Supra-glottic airway Device (SAD). Group A (Baska) \& group B ( I-gel). Inclusion Criteria: Age: 18-55, American Society of Anesthesia (ASA) 1 or 2, BMI\<35 \& Low risk of aspiration. Exclusion Criteria: Anticipated upper airway problem, Gastrointestinal tract (GIT, disease, pregnancy \& High risk of aspiration. Methodology: All patients received fentanyl 1 micro gram/Kg, Propofol(2-4mg/Kg) was titrated to induce anesthesia, followed by manual ventilation with sevoflurane (2-4%) in Oxygen.All devices were inserted by one of 2 investigators. Data collection: 1- Demographic Data: age,weight,height.2-duration of anesthesia.3- Data related to device insertion: Time of insertion,duration of anesthesia, seal pressure,peak airway pressure, Fiberoptic (FO)view of the larynx ,vomiting or regurgitation, postoperative laryngeal spasm or blood on the device after removal. Primary outcome: To detect seal pressure and fitting against laryngeal aperture detected by FO. Secondary outcome:To determine Peak pressure, incidence of complications: vomiting or regurgitation, blood on the device after removal (indicating trauma to the airway) or postoperative laryngeal spasm.. Statistical analysis: For analysis of continuous variables independent sample t-test will be applied and for categorical variables chi-square test will be used.value of p\<0.05 will be considered significant. Sample size: Sample size was calculated using EpiCalc program using the following data : mean seal pressure for Baska :29.98 , mean seal pressure for I-Gel: 25.62. SD: 4.9 , study power 80% confidence interval . P value\<0.05. the calculated sample size was found to be 19 for each group (overall 38), so the investigators will allocate 30 patient in each group to avoid drop out. Statistical analysis: Source of funding This study will be attributed to Department of Anesthesiology, Faculty of medicine, Cairo University. Support will be provided solely from departmental sources. Keywords: Baska, I-Gel, Supra-glottic airway devices, seal pressure
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | laryngeal mask insertion (Baska) | |
| DEVICE | laryngeal mask insertion (I-gel ) |
Timeline
- Start date
- 2016-06-01
- Primary completion
- 2016-12-01
- Completion
- 2017-08-01
- First posted
- 2017-05-04
- Last updated
- 2017-05-04