Clinical Trials Directory

Trials / Unknown

UnknownNCT03129711

Patient Satisfaction of Glazed IPS Empress CAD Versus Glazed Celtra Duo Ceramic Laminate Veneers

Patient Satisfaction and One Year Clinical Evaluation of Glazed IPS Empress CAD Versus Glazed Celtra Duo Ceramic Laminate Veneers

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
36 (estimated)
Sponsor
Cairo University · Academic / Other
Sex
All
Age
18 Years – 60 Years
Healthy volunteers
Not accepted

Summary

The most frequent reason for failure of laminate veneers made of glass ceramics (feldspathic, leucite based and lithium silicate based ceramics) was fracture of the ceramic, Therefore, ceramic materials that have higher fracture resistance, especially for patients suffering from abnormal occlusion, are needed.

Detailed description

IPS Empress CAD is a leucite glass-ceramic of the SiO2-Al2-O3-K2O material systems with leucite crystal ranging from 5 to 10 µm in size. The leucite crystals increase the material strength and interferes with crack propagation, while the fracture energy is absorbed by the crystalline phase. The resistance and flexural strength (160 Mpa) is improved by the difference in the coefficient of thermal expansion between the glass phase and the crystalline phase and the cooling process following sintering phase. CELTRA DUO: is a new generation of glass ceramic material. With the aid of a new manufacturing process, the glass ceramic is infiltrated with 10% zirconia by weight, producing zirconia reinforced lithium silicate ceramic (ZLS). The material is characterized by a unique homogenous structure with fine grains that provides excellent material quality and consistency, high strength properties and long term performance. In addition, the material offers satisfying processing characteristics which can be milled and polished easily. After milling the restorations are shaded correctly shaded, with no need for crystallization step 10. The milled restorations have a flexural strength of 210 MPa. After stain and glaze firing the restoration will exhibit a flexural strength up to 370 MPa.

Conditions

Interventions

TypeNameDescription
OTHERglazed Celtra Duozirconia reinforced lithium silicate
OTHERIPS Empress CADStandard etchable glass ceramic for laminate veneers

Timeline

Start date
2017-08-01
Primary completion
2018-08-01
Completion
2018-09-01
First posted
2017-04-26
Last updated
2017-05-02

Source: ClinicalTrials.gov record NCT03129711. Inclusion in this directory is not an endorsement.