Summary

This study is a single-center, prospective, observational study designed to subjects presenting with stable angina pectoris or acute coronary syndromes requiring treatment of de novo lesions. Eligible subjects will have BVS scaffold implant using a high pressure post-scaffold implantation ballooning, designed to specifically address the issue of incomplete BVS expansion. OCT ( optical coherence tomography ) will be used to evaluate the change in the intraluminal scaffold volume and the prevalence of scaffold embedding from post-scaffold implantation to post-dilation high pressure (16-20 atm), non-compliant ballooning in relation to the underlying plaque.

Detailed description

This study is a single-center, prospective, observational study designed to enroll 50 subjects presenting with stable angina pectoris or acute coronary syndromes requiring treatment of de novo lesions. Consented subjects are to undergo PCI and have a lesion without angiographic calcification. Eligible subjects who meet inclusion and exclusion criteria for BVS scaffold implant will have a BVS-specific implantation protocol with high pressure post-scaffold implantation ballooning, designed to specifically address the issue of incomplete BVS expansion. Because the scaffold is compliant, a perfectly embedded scaffold is sometimes observed in a lesion with soft plaque, resulting in a smaller intra-luminal scaffold volume that may reduce the event rate. Enrolled subjects will have OCT ( optical coherence tomography ) pre and post BVS implantation to assess the change in the intraluminal scaffold volume and the prevalence of scaffold embedding from post-scaffold implantation (using the moderate pressure of 12 atm) to post-dilation high pressure (16-20 atm), non-compliant ballooning in relation to the underlying plaque.

Conditions

Interventions

TypeNameDescription
DEVICEBioresorbable vascular scaffolds, OCT, non-compliant ballooningMeasure the effect of high-pressure, NC ballooning on scaffold embedding by OCT

Timeline

Start date
2017-03-30
Primary completion
2018-03-22
Completion
2018-06-30