Infrared Choroidal Reflectance Camera for the Detection of Childhood Cataract

Proof of Concept Trial of a Novel Imaging System to Assess and Document Choroidal Reflectance in Children for the Detection of Cataract and Media Opacities.

Status
Completed
Phase
Study type
Observational
Enrollment
110 (actual)
Sponsor
Cambridge University Hospitals NHS Foundation Trust · Academic / Other
Sex
All
Age
1 Month – 5 Years
Healthy volunteers
Accepted

Summary

Sensitivity and specificity of current screening methods for childhood cataracts is poor. This results in delayed diagnosis and management which can decrease the visual prognosis following cataract surgery. It also results in many false positives with resultant unnecessary healthcare costs in specialist paediatric ophthalmology services. This study compares the accuracy of cataract screening using infrared light compared to white light in a population of children attending eye clinic.

Detailed description

All babies born in the United Kingdom (UK) undergo eye screening to enable the early diagnosis and management of childhood cataract, a treatable but potentially blinding condition affecting 1 in 2000 newborns. The current technique involves the assessment of the "red-reflex" - the orange/red glow in the pupil seen during ophthalmoscopy (or flash photography) due to reflectance of light from the back of the eye. In reality, testing can be technically difficult because the pupil constricts to light during the examination and, particularly in babies of Asian and Afro-Caribbean ancestry, the red-reflex can be dim due to the effect of ocular pigmentation. As a result less than 50% of congenital cataracts are currently identified up by screening. Early visual experience is required for good visual development and a delay in the surgical management of cataracts results in sub-optimal visual development and visual impairment. There are theoretical advantages to using Infrared (IR) light rather than white light to assess choroidal reflectance, including avoidance of pupil constriction. The study aims to determine if the assessment of the IR-reflex, using a prototype device, rather than the red-reflex, using a direct ophthalmoscope, improves screening accuracy in the detection of ocular media opacities in a pathology enriched childhood cohort. Eligible children attending an eye clinic will be screened for cataract by a medical student (masked to the pathology) using the existing standard direct ophthalmoscope technique for red-reflex assessment and IR-reflex assessment using the prototype imaging device. A gold standard examination by an ophthalmologist will follow the screening examinations. Sensitivity and specificity of each screening technique will be calculated and compared.

Conditions

Interventions

TypeNameDescription
DIAGNOSTIC_TESTRed-reflex assessmentThe red reflex was examined in the standard manner using direct ophthalmoscope by medical student examiner
DIAGNOSTIC_TESTInfrared-reflex assessmentThe infrared reflex was examined using a modified smart phone camera by a medical student examiner

Timeline

Start date
2017-02-01
Primary completion
2017-09-01
Completion
2017-09-01
First posted
2017-01-30
Last updated
2023-11-07
Results posted
2023-11-07

Locations

1 site across 1 country: United Kingdom

Source: ClinicalTrials.gov record NCT03035292. Inclusion in this directory is not an endorsement.