Clinical Trials Directory

Trials / Withdrawn

WithdrawnNCT03027323

Washington Study of AxoTrack-Guided Central Venous Cannulation

Status
Withdrawn
Phase
N/A
Study type
Interventional
Enrollment
0 (actual)
Sponsor
University of Washington · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

Undifferentiated hypotension is a medical emergency where a patient's blood pressure drops to critical levels due to several possible reasons. The medical staff treating the patient will need to find out the reason for your drop in blood pressure as soon as possible. When treating low blood pressure, the medical staff typically performs a procedure called central venous cannulation (CVC). CVC involves accessing a large vein (usually the subclavian under the collarbone) by inserting a needle into the vein. By doing this, the medical staff can measure the pressures in the patient's veins or give medicine to the patient while they are in the hospital. The purpose of this study is to compare the time needed to complete CVC using the AxoTrack device to CVC guided by landmarks on a patient's body. The investigators expect that there will be a maximum of 30 patients enrolled in this study.

Detailed description

Central venous cannulation (CVC) is commonly performed to give volume resuscitation and parenteral medications to patients with time sensitive conditions such as severe traumatic injury or undifferentiated shock. CVC via the subclavian route is associated with more frequent technical complications but less frequent infection or thrombosis as compared with via the internal jugular or femoral veins. Traditionally CVC via the subclavian vein is guided by anatomical landmarks. CVC guided by real-time use of traditional diagnostic ultrasound device is associated with a lower technical failure rate (overall and on first attempt), fewer punctures, faster access, and fewer mechanical complications as compared with guidance by anatomical landmarks when performed via the internal jugular vein. It remains unclear whether CVC guided by real-time ultrasound is associated with significantly lower failure and complication rates as compared with CVC guided by landmarks when performed via the subclavian vein. CVC guided by real-time ultrasound may reduce the incidence of complications, number of punctures, and the time between skin penetration and the aspiration of venous blood into the syringe as compared with guidance by landmarks. A limitation of guidance by a traditional diagnostic ultrasound device is it that it may require an assistant to perform, which may not be feasible when treating time sensitive conditions or in low resource settings. In addition, most traditional ultrasound probes are not designed to image the subclavian vein behind the clavicle. The AxoTrack system is a novel ultrasound guidance system recently cleared for human use by the United States Food and Drug Administration. It is intended to facilitate CVC by a single operator as well as to reduce complications and time associated with CVC. The AxoTrack has a small ultrasound scan head which facilitates imaging of the subclavian vein. It remains unclear whether CVC guided by AxoTrack reduces procedure times and complication rates when compared with CVC using landmark guidance in patients with undifferentiated hypotension.

Conditions

Interventions

TypeNameDescription
DEVICEAxoTrack SystemThe AxoTrack system is a novel ultrasound guidance system intended to facilitate central venous cannulation (CVC) by a single operator as well as to reduce complications and time associated with CVC. The AxoTrack has a small ultrasound scan head which facilitates imaging of the subclavian vein.

Timeline

Start date
2017-02-10
Primary completion
2020-12-01
Completion
2020-12-01
First posted
2017-01-23
Last updated
2022-10-28

Locations

1 site across 1 country: United States

Regulatory

Source: ClinicalTrials.gov record NCT03027323. Inclusion in this directory is not an endorsement.