Trials / Terminated
TerminatedNCT03013855
Efficacy of Fecal Immunochemical Test Using Digital Rectal Exam
- Status
- Terminated
- Phase
- Phase 1
- Study type
- Interventional
- Enrollment
- 1 (actual)
- Sponsor
- Boston Medical Center · Academic / Other
- Sex
- All
- Age
- 50 Years – 75 Years
- Healthy volunteers
- Accepted
Summary
This study will investigate the use of digital rectal exam (DRE) to obtain stool samples for the fecal immunochemical test (FIT) in patients due for screening colonoscopy and in pre-operative patients with known colorectal cancer. FIT is currently FDA-approved for spontaneous stool and DRE, however, samples are not commonly obtained by DRE. In addition, some clinicians remain skeptical about the accuracy of FIT using stool obtained from DRE. This study aims to assess the correlation between FIT using the stool sample from DRE (FIT-DRE) and standard of care FIT (FIT-SOC). If good correlation is shown, the investigators may be able to demonstrate efficacy of FIT using a DRE in the clinic setting. This may help avoid logistical barriers, as well as improve compliance and adherence to colon cancer screening in the outpatient setting, eventually leading to improved quality of care.
Detailed description
Fecal immunochemical testing (FIT) is an FDA-approved stool-based screening test for colorectal cancer. It offers a less invasive colorectal cancer screening option for patients who are not agreeable to colonoscopy and measures the level of Ab-globin complexes in the stool without direct interference with diet or medications. FIT has been shown to be selective for colorectal bleeding, as globin from the upper GI tract is digested by proteolytic enzymes. A meta-analysis of studies analyzing FIT showed a pooled sensitivity of 0.79 (95% CI 0.69-0.86) and specificity was 0.94 (CI 0.92-0.95). In a large study comparing FIT with another stool-based screening test, gFOBT, sensitivity of FIT was found to be 0.53-0.73 for CRC and 0.20-0.25 for advanced neoplasia compared to gFOBT, which showed 33.3% for CRC and 8.6% for advanced neoplasia. In addition, FIT requires fewer stool samples and the lack of dietary or medication modifications. As a result, compliance is likely to be higher, which is crucial for cancer detection. A challenge inherent to stool-based screening tests is compliance with sample submission by the patients. FIT is meant to improve logistical barriers to screening because only one sample is needed, however, compliance rates with standard of care FIT (FIT-SOC) is approximately 50%. FIT using stool from a digital rectal exam (DRE) performed during a clinic visit may be an effective screening tool for patients preferring stool-based screening. FIT has been FDA-approved for the testing of spontaneously passed stool, as well as stool collected by DRE. Manufacturers of FIT have claimed that DRE provides a sufficient amount of stool for sampling, however, there are no validated studies to our knowledge which demonstrate adequate efficacy. As a result, FIT using DRE is not commonly done in clinical practice. This study aims to assess the correlation of FIT using DRE (FIT-DRE) with standard of care FIT (FIT-SOC) as a method of obtaining stool samples.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | FIT-SOC | Study subjects will be given a standard kit for fecal immunochemical test by their primary healthcare provider. As per standard practice, the patient will take the kit home and use the included FIT applicator to collect a stool sample from spontaneously passed stool during a regular bowel movement. The patient will then mail the stool sample to the lab in a pre-paid envelope, which is provided in the kit. |
| DEVICE | FIT-DRE | Study subjects will have a digital rectal exam completed by their primary care providers during the physical exam portion of a routine clinic visit. The stool collected on the examiner's finger will be applied to the FIT applicator in the standard kit, which will then be sent to the lab for processing. |
Timeline
- Start date
- 2016-07-01
- Primary completion
- 2017-07-01
- Completion
- 2017-07-01
- First posted
- 2017-01-09
- Last updated
- 2017-07-31
Locations
1 site across 1 country: United States
Regulatory
- FDA-regulated device study
Source: ClinicalTrials.gov record NCT03013855. Inclusion in this directory is not an endorsement.