Clinical Trials Directory

Trials / Completed

CompletedNCT03012633

Rapid Diagnostic of Hyperfibrinolysis in Liver Transplantation

Status
Completed
Phase
Study type
Observational
Enrollment
30 (actual)
Sponsor
University Hospital, Bordeaux · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

During liver transplantation (LT), hyperfibrinolysis is one of the most important modification of haemostasis. It is associated with t-PA and protein C increased activity. Hyperfibrinolysis is frequent, hardly predictable and associated with major bleeding. The diagnostic of hyperfibrinolysis with standard laboratory tests (euglobulin lysis test, t-PA, PAI-1 and D-dimers dosages) does not provide an answer in a delay compatible with the clinical practice in the operating room. The "Lysis Timer" is a device developed by Hyphen-Sysmex in collaboration with SD Innovation and Charleroi University Hospital (Belgium). It allows the implementation of the "Global Fibrinolytic Capacity", or GFC test, in a complete system associating i) the reagents for in vitro triggering of the clot and its lysis (contact system activators, t-PA, thrombin and calcium), ii) the signal acquisition by the Lysis Timer (able to convert the analogic signal of the absorbance modifications related to clot formation into a numeric signal) and iii) a dedicated software treating the numeric signal to define clot lysis time. The GFC test, using t-PA to shorten signal acquisition times, is particularly adapted to the diagnosis of hyperfibrinolysis with PAI-1 collapse, of which LT is an example.

Detailed description

The primary aim of this prospective, monocentric, observational study is to evaluate the Lysis Timer as a rapid diagnostic device for hyperfibrinolysis during liver transplantation. Lysis times provided by this device will be compared to the euglobulin lysis times and to the others parameters of fibrinolysis at the different stages of liver transplantation and more specifically at the anhepatic stage and after graft revascularization. The secondary aims are to compare the results of the Lysis Timer, the thromboelastogram, the thrombin generation test and the standard laboratory tests in the context of hyperfibrinolysis during liver transplantation.

Conditions

Interventions

TypeNameDescription
DEVICELysis timerLysis Timer compared with standard laboratory test to diagnose hyperfibrinolysis during liver transplantation.

Timeline

Start date
2017-01-09
Primary completion
2017-06-14
Completion
2017-07-12
First posted
2017-01-06
Last updated
2024-05-17

Locations

1 site across 1 country: France

Source: ClinicalTrials.gov record NCT03012633. Inclusion in this directory is not an endorsement.