Clinical Trials Directory

Trials / Completed

CompletedNCT03003585

Effects of Direct Laryngoscopic and Fiberoptic Intubation on Intraocular Pressure

Comparison of Effects of Direct Laryngoscopic and Fiberoptic Oral Endotracheal Intubation on Intraocular Pressure

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
54 (actual)
Sponsor
Inonu University · Academic / Other
Sex
All
Age
18 Years – 65 Years
Healthy volunteers
Not accepted

Summary

In this study, the investigators aimed to compare the effects of direct laryngoscopic and fiberoptic endotracheal intubation on intraocular pressure.

Detailed description

Material and Method: Total of 54 American Society of Anesthesiologist Grade 1-2, Mallampati score 1 or 2, age between 18 to 65 patient planned to undergo nonopthalmic surgery will be included to study. Patients with glaucoma, diabetes mellitus, cardiovascular and pulmonary diseases, American Society of Anesthesiologist Grade III and IV, body mass index more than 35, difficult intubation, undergo obstetrical surgery and propofol, fentanyl, rocuronium contraindicated will be excluded from the study. Patients will be divided randomly into 2 groups as direct laryngoscopic and fiberoptic intubation group. Patients will be preoxygenated with %100 O2 for 3 minutes then anesthesia will be induced using propofol 2 mg / kg, fentanyl 1 mcg/kg, and rocuronium 0,5 mg / kg in both groups. After 3 minutes mask ventilation, patients will be intubated (women with No:7-7,5, men with No:8-8,5 intubation tube). Systolic blood pressure, diastolic blood pressure, mean arterial pressure, peripheral oxygen saturation,perfusion index will be recorded and intraocular pressure measured by ophthalmologist by tonopen device will be recorded pre-induction (basal), after induction, 1,2,3,5 minutes after intubation, respectively. Period between handling of laryngoscope or fiberoptic device after termination of mask ventilation and obtain end tidal CO2 will be accepted as application time and recorded. Study will be terminated after 5th minute values taken.

Conditions

Interventions

TypeNameDescription
OTHERDirect laryngoscopeThis device is used in endotracheal intubation and tonopen device for measuring of intraocular pressure. The investigators want to evaluate which one is better.
OTHERFiberoptic bronchoscopeThis device is used in endotracheal intubation and tonopen device for measuring of intraocular pressure. The investigators want to evaluate which one is better.

Timeline

Start date
2016-12-01
Primary completion
2017-02-01
Completion
2017-04-04
First posted
2016-12-28
Last updated
2017-04-05

Source: ClinicalTrials.gov record NCT03003585. Inclusion in this directory is not an endorsement.