Trials / Completed
CompletedNCT03001791
Comparison of ER:YAG Laser, CO2 Laser and Scalpel Excision of Fibrous Hyperplasia on the Buccal Mucosa
Clinical and Histopathological Comparison of ER:YAG Laser, CO2 Laser and Scalpel Excision of Fibrous Hyperplasia on the Buccal Mucosa
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 75 (actual)
- Sponsor
- University of Bern · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Accepted
Summary
The aim of the RCT is to analyse clinical and histopathological particularities for excisional biopsies of fibrous hyperplasia in the buccal mucosa performed with Er:YAG laser, CO2 laser and scalpel. The primary outcome parameter is to evaluate the thermal damage zone on the excised specimens. Secondary parameters are time of surgery, intraoperative bleeding, the need for additional electrocoagulation or sutures and patient's postsurgical perception of pain, other postsurgical effects and use of analgesics.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| PROCEDURE | Excisional biopsy with Er:YAG laser | Excisional biopsy of fibrous hyperplasia in the buccal mucosa in local anesthesia with Er:YAG laser (Lite TouchTM, Synergon Dental Lasers, Light instruments Ltd., Yokneam Elite, Israel), λ = 2940nnm. Soft tissue biopsy mode with water cooling, frequency 35 Hz, pulse duration 250-390 µsec, pulse energy of 200 mJ, power 7 Watt . Cylindrical sapphire tip, 400 µm in diameter, without contact to the tissue. |
| PROCEDURE | Excisional biopsy with CO2 laser | Excisional biopsy of fibrous hyperplasia in the buccal mucosa in local anesthesia with CO2 laser (Spectra DENTA Surgical Carbon Dioxide Laser, MAX Engineering Ltd., Gyeonggi-Do, Korea), λ = 10'600nnm. cf mode (frequency 140 Hz, pulse duration 400 µsec, pulse energy 33 mJ,a power 4.62 watts). Laser beam with a spot size of 0.2 mm, non-contact mode. |
| PROCEDURE | Excisional biopsy with scalpel | Excisional biopsy of fibrous hyperplasia in the buccal mucosa in local anesthesia with scalpel (blade 15C). Polyamide sutures (Seralon 5-DS15, Serag Wiessner KG, Naila, Germany). |
Timeline
- Start date
- 2013-07-01
- Primary completion
- 2017-07-04
- Completion
- 2017-08-10
- First posted
- 2016-12-23
- Last updated
- 2017-11-27
Locations
1 site across 1 country: Switzerland
Source: ClinicalTrials.gov record NCT03001791. Inclusion in this directory is not an endorsement.