Clinical Trials Directory

Trials / Unknown

UnknownNCT02996929

Safety and Performance of LeadExx LC System in Lead Extraction

Prospective, Investigational Study to Assess the Safety and Performance of LeadExx LC System in Lead Extraction

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
10 (estimated)
Sponsor
LeadExx Cardiac Ltd. · Industry
Sex
All
Age
18 Years – 75 Years
Healthy volunteers
Not accepted

Summary

The study's main purpose is to evaluate the safety and performance of the LeadExx LC System and its ability to safely extract leads. The study will enroll 10 patients scheduled for CIED lead extraction. The decision upon lead extraction will be based upon the applicable Heart Rhythm Society guidelines or European Heart Rhythm Association (EHRA).

Detailed description

The use of implantable cardiac devices has been exponentially increasing, and lead extraction has become a necessary procedure. But lead extraction has potentially serious complications, including venous or myocardial tear, cardiac tamponade, and even death. Powered sheaths, such as Excimer laser or a radiofrequency system, have been used for extraction of ICD or pacemaker leads. However, the Heart Rhythm Society (HRS) has stated that "possible predictors of major complications were implant duration of the oldest lead, female gender, ICD lead removal, and use of the laser extraction technique, multiple leads, and calcified leads". To reduce the risk of the lead extraction procedure and therefore reduce the number of abandoned leads, LeadExx had developed its system. The LC system is an active disposable system provided sterile for single use. The system is comprised of the following two main parts: a. Dilation Unit (DU) - (invasive, sterile) b. Control Unit- (CU) - (non-invasive, sterile fluid path) The physical connection between the units is achieved by 3 Luer locks that connect the CU Solenoids' output to 3 flexible tubes at the proximal end of the DU. 1. Dilation Unit (DU): The dilation unit is an invasive sterile unit, comprised of a dilation tip and a connecting shaft. The unit is activated using a hydraulic mechanism. The dilation tip is threaded over the lead, inserted into the vessel together with its connecting shaft and while advancing along the lead, dilates the surrounding tissue and ultimately enables the lead removal from the vein. 2. Control Unit (CU): The Control Unit is a non-invasive fluid path sterile unit, comprised of various off the shelf modules . The unit is being filled with sterile Saline just prior to its operation and by synchronizing the transfer of the Saline into the DU controls its advancement. I

Conditions

Interventions

TypeNameDescription
DEVICELC SystemSubjects will undergo CIED lead extraction with the LC system

Timeline

Start date
2017-02-01
Primary completion
2017-02-01
Completion
2017-04-01
First posted
2016-12-19
Last updated
2016-12-19