Clinical Trials Directory

Trials / Unknown

UnknownNCT02971917

A Clinical Study of TRUVIEW ART™(Advanced Reconstruction Tech)to Improve Image Quality on Chest Radiograph

A Clinical Study of TRUVIEW ART(Advanced Reconstruction Tech)to Improve Image Quality on Chest Radiograph

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
50 (estimated)
Sponsor
Seoul National University Hospital · Academic / Other
Sex
All
Age
21 Years
Healthy volunteers
Accepted

Summary

To validate the following theory: "With TRUVIEW ART™ applied a detector's quantitative performance index, MTF(Modulation Transfer Function), is increased 20% or more". This is to examine the effect of the increased MTF index, whether it influences or not the interpreter's preference

Detailed description

Background of Study : DRTECH Corp. has developed and applied for patenting the unique technology of TRUVIEW ART™. TRUVIEW ART™ is advanced image reconstruction technology that restores image quality from the side effects of scattering signals in indirect type scintillator detectors. It is an advanced image pre-processing technology that constructs signal scattering models (PSF) of indirect type detector scintillators. Image sharpness (MTF) is improved by predicting scattering models and eliminating the scattering signal. Purpose of Research and Assumption : Indirect conversion type detectors using scintillators are universal in today's diagnostic imaging area. However, they have a disadvantage of signal scattering compared with direct conversion type detectors. TRUVIEW ART™(Advanced Reconstruction Technology) can restore images from the scattering problems. The purpose of this study is to verify how well it improves the usefulness in clinical diagnostic imaging. Evaluation will measure the improvements in MTF, which is the quantitative performance index of a detector.

Conditions

Interventions

TypeNameDescription
RADIATIONChest x-ray image acquisitionObtain a digital X-ray chest image of the patient
RADIATIONCreation of TRUVIEW ART applied imageApplication of TRUVIEW ART to the original chest x-ray image to create a new set of TRUVIEW ART applied image. Outcome: 2 versions of chest image 1. Original Chest X-ray (w/o TRUVIEW ART) 2. TRUVIEW ART applied image
RADIATIONComparison of TRUVIEW ART image with original imageComparison of 2 versions of chest image side by side Performance evaluation may consist of detailed categories such as expression of chest structure, visibility level of pulmonary vascular system, etc. For all categories visibility and preference will be scored and each category will be analyzed to point out any statistical difference

Timeline

Start date
2016-11-01
Primary completion
2017-05-01
Completion
2017-05-01
First posted
2016-11-23
Last updated
2016-11-23

Locations

1 site across 1 country: South Korea

Source: ClinicalTrials.gov record NCT02971917. Inclusion in this directory is not an endorsement.