Trials / Completed
CompletedNCT02965547
Remote Ischemic Preconditioning of Dynamic Cerebral Autoregulation in Healthy Adults
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 50 (actual)
- Sponsor
- Yi Yang · Academic / Other
- Sex
- All
- Age
- 18 Years – 70 Years
- Healthy volunteers
- Accepted
Summary
The purpose of this study is to determine the impact of remote ischemic preconditioning on dynamic cerebral autoregulation and related hematology indexes in healthy adults.
Detailed description
Remote ischemic preconditioning(RIPC) is the phenomenon whereby brief cycles of ischemia and reperfusion, applied to a distant organ, provide protection to the target organ. Dynamic cerebral autoregulation(dCA), a mechanism to maintain the cerebral blood flow, has been proved to be critical for the occurrence,development and prognosis of ischemic neurovascular disease. In this study, we hypothesis that RIPC provides neuro-protection by means of improving dCA.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | Remote ischemic conditioning equipment | The RIPC consisted of 4 cycles of extremities ischemia (5-minute blood-pressure cuff inflation to 200 mm Hg, followed by 5-minute cuff deflation). The tourniquets were applied to one side upper arm and other side thigh. This intervention was undertaken one time in total. |
| PROCEDURE | Intravenous blood collection | Nurses will collect intravenous blood 6ml twice(at baseline and 1h after RIPC).The blood samples will be stored for laboratory test.The blood samples only use for the trial. |
| PROCEDURE | dCA measurement | Serial measurements of dCA were performed at 7 time points, baseline, 1h, 3h, 6h, 9h, 12h, 24h after RIPC.The continuous ABP was measured non-invasively using a servo-controlled plethysmograph (Finometer Pro, the Netherlands) at the middle finger. Two 2 MHz transcranial Doppler probe was used to measure continuous cerebral blood flow velocity (CBFV) simultaneously in the bilateral middle cerebral arteries at a depth of 45-60 mm Endtidal CO2 was monitored using a capnograph (MultiDop X2, DWL, Sipplingen, Germany). The probes were placed over temporal windows and fixed with a customized head frame. CBFV and continuous arterial blood pressure were recorded simultaneously from each subject in the supine position for 10 minutes. All data were recorded for further assessment and analysis. |
Timeline
- Start date
- 2017-01-01
- Primary completion
- 2017-05-01
- Completion
- 2017-07-25
- First posted
- 2016-11-16
- Last updated
- 2021-08-24
Locations
1 site across 1 country: China
Source: ClinicalTrials.gov record NCT02965547. Inclusion in this directory is not an endorsement.