Auto-PAP for Pulmonary Hypertension Treatment in Decompensated HF Patients With Sleep Apnea.
Auto-PAP for Pulmonary Hypertension Treatment in Decompensated Heart Failure Patients With Obstructive Sleep Apnea: A Two Center Pilot Study
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 21 (actual)
- Sponsor
- Albert Einstein Healthcare Network · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
The objective of the study is to evaluate the effect of continuous positive airway pressure (PAP) therapy on pulmonary arterial (PA) pressures in acute decompensated heart failure (HF) patients with obstructive sleep apnea (OSA). The study will also assess changes in functional parameters, biomarkers, and echocardiographic parameters.
Detailed description
The ASAP-HF study is a prospective, randomized, controlled, two-center, study with a parallel group design, with subjects randomized to either control (no APAP) or active treatment (APAP) in a 1:1 ratio. Group A (active): standard medical therapy plus treatment with continuous APAP for 48hrs, or Group B (control): standard medical therapy only. Many people who have heart failure (HF) also have sleep-disordered breathing (SDB), which is breathing irregularities during sleep. These irregularities may interrupt the sleep as well as increase the rate of progression of Heart Failure. The ASAP-HF study is being done to see if certain clinical outcomes are improved in acute decompensated heart failure (HF) patients with SDB by using a non-invasive breathing device continuously for a short period of time (48 hours) while patient is still in the hospital. The device is called AirSense™ 10 AutoSet (AutoSet). It consists of an air flow generator, air tubing, an air humidifier, and a mask. As the patient breathe through the mask, the AutoSet monitors breathing. The primary objective of this pilot study is to evaluate the effect of continuous positive airway pressure (PAP) therapy on pulmonary arterial (PA) pressures in acute decompensated heart failure (HF) patients with obstructive sleep apnea (OSA). The study will also assess changes in functional parameters, biomarkers, and echocardiographic parameters . This device is not currently used to diagnose sleep apnea and its utility is not well studied. This study will establish the utility of the device in diagnosing sleep apnea.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | AirSense™ 10 AutoSet | The AirSense 10 AutoSet is a device that provide non-invasive ventilatory support to treat patients with sleep disordered breathing. The device is intended for home and hospital use. The treatment pressure required by the patient may vary due to changes in sleep state, body position and airway resistance. In AutoSet mode, the device provides only that amount of pressure required to maintain upper airway patency. The AirSense 10 AutoSet provides a minimum and maximum pressure within the range of 4-20 cm of water. |
| OTHER | Standard Medical Therapy | Standard medical therapy according to current guidelines. |
Timeline
- Start date
- 2016-10-01
- Primary completion
- 2017-08-01
- Completion
- 2018-08-15
- First posted
- 2016-11-15
- Last updated
- 2020-03-30
- Results posted
- 2020-03-30
Locations
2 sites across 2 countries: United States, Germany
Source: ClinicalTrials.gov record NCT02963597. Inclusion in this directory is not an endorsement.