Clinical Trials Directory

Trials / Unknown

UnknownNCT02957006

Discrimination of P and T Waves With Linq and Holter

Discrimination of P and T-waves With Linq and Holter

Status
Unknown
Phase
Study type
Observational
Enrollment
20 (estimated)
Sponsor
TriHealth Inc. · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

Currently loop recorders diagnose arrhythmias and send automatic alerts to physicians based on R to R relationships only. We believe arrhythmia diagnostics could be improved if accurate detection of P and T waves as well as QRS complexes were possible. There is no technique available for long term outpatient monitoring of QT intervals for patient at risk of torsade de pointes when receiving QT prolonging drugs. We believe that if an accurate T wave detection algorithm were developed loop recorders could be used to monitor the QT interval, and perhaps even provide alerts for patients at risk. The objective of this study is to see if an algorithm can be developed to accurately define P and T waves using data from an implantable loop recorder.

Detailed description

Pilot Study of 20 prospective cardiology patients with loop recorders currently implanted for standard clinical indications. Eligible Subjects will be brought into the office of John Wilson, MD or Marshall Winner, MD. After informed consent is obtained from Hatton Research Staff the following will be performed: * subjects will have an initial loop recorder download to USB flash drive * 12 lead EKG * Annotated QT intervals on a 30 second rhythm strip * 24 hour Holter monitor placed by Hatton Research Staff in order to confirm the loop recorder data. * Subjects will be instructed on the Holter monitors care and use. * Subjects will be scheduled to come back to the office after 24 hours to return the Holter monitor and have a final loop recorder download completed. * Data from the loop recorder, Holter monitor, 12 lead EKG, and 30 second rhythm strip will be downloaded and de-identified per Hatton Research Staff. * All de-identified data from the initial loop recorder download, 12 lead EKG, 30 second rhythm strip, final loop recorder download, and Holter monitor will be sent to Medtronic for algorithm development. Independent Variables: These variables include age and race Dependent Variables: These variables include the data from the loop recorder, 12 lead EKG, Holter monitor and 30 second rhythm strip. Intervention or experimental aspect of the study Subjects will have a 12 lead EKG performed with 30 second rhythm strip Subjects will complete a period of 24 hours in which they will wear a Holter monitor applied by Hatton Research Staff. Statistical Analysis * Descriptive statistics (mean, standard deviation) will be calculated for all continuous variables. Continuous variables will be compared using Student's - T test or ANOVA as appropriate. * Frequency and percentages will be calculated for all categorical variables. * Categorical data will be compared using chi square or Fisher's Exact Test as appropriate * Data variables will be assessed by Hatton Research Specialist

Conditions

Interventions

TypeNameDescription
DEVICELoop RecorderObservation of Loop Recorder implanted for clinical reasons

Timeline

Start date
2016-10-01
Primary completion
2018-12-01
Completion
2018-12-01
First posted
2016-11-07
Last updated
2018-03-23

Locations

1 site across 1 country: United States

Source: ClinicalTrials.gov record NCT02957006. Inclusion in this directory is not an endorsement.