Balloon Catheter vs. Basket Catheter for Endoscopic Bile Duct Stone Extraction

Balloon Catheter Versus Basket Catheter for Endoscopic Bile Duct Stone Extraction in Patients With Periampullary Diverticulum:a Multicenter Randomized Trial

Status
Completed
Phase
Phase 4
Study type
Interventional
Enrollment
80 (actual)
Sponsor
Anhui Provincial Hospital · Other Government
Sex
All
Age
18 Years – 80 Years
Healthy volunteers
Not accepted

Summary

Endoscopic bile duct stone (BDS) removal is a well-established treatment; however, the preference for basket or balloon catheters for extraction is operator-dependent It is reported that complete endoscopic treatment with a single catheter is more likely when choosing a balloon catheter over a basket catheter for extraction of BDSs≤10mm. However, a study comparing the two catheter types in patients with periampullary diverticulum has not been performed, and there is no strong basis on which to recommend the balloon catheter as a first-line stone removal device. The investigators therefore conducted a multicenter prospective randomized trial to compare catheter performance in patients with periampullary diverticulum.

Detailed description

A prospective, multi-center, investigator sponsored, randomized controlled trial, 80 subjects will be randomly assigned to groups that were treated with basket or balloon catheters. A descriptive analysis will be performed on primary endpoint, containing frequency of number and percentage of patients. A two proportion equality test will be conducted to explore whether incidence rates are different.Descriptive statistics including number (N), mean, median, standard deviation, minimum and maximum, will be produced for all continuous variables. Frequency tables of number (N) and percentage of subjects will be produced for all categorical variables.

Conditions

Interventions

TypeNameDescription
DEVICEBalloon catheterBalloon stone extraction was carried out with a balloon catheter \[Extractor Pro RX \[M00547000, M00547010, or M00547020\]; Boston Scientific,Shang hai,China). The Extractor Pro has multiple sizes (9-12, 12-15, and 15-18mm), the choice being made on the basis of the CBD diameter. It has a contrast-injection hole above the balloon for the performance of balloon occlusion cholangiography (BOC).
DEVICEBasket catheterBasket stone extraction was performed with a basket catheter (Flower Basket V \[FG-V435P or FG-V425PR\]; Olympus Corp., Shang hai,China).

Timeline

Start date
2014-11-01
Primary completion
2016-11-01
Completion
2016-11-01
First posted
2016-09-21
Last updated
2016-12-14

Locations

1 site across 1 country: China