Trials / Completed
CompletedNCT02909530
Comparison Between Olympus EZ Shot 3Plus 19G and EZ Shot 2 19G in EUS-guided FNB of Solid Pancreatic Masses
Comparison Between the Olympus EZ Shot 3Plus 19G and EZ Shot 2 19G in Endoscopic Ultrasound-guided Fine Needle Biopsy of Solid Pancreatic Masses
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 46 (actual)
- Sponsor
- University of Ulm · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
Endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) is a valid and recommended technique for tissue diagnosis of pancreatic masses. However, the diagnostic yield is with a sensitivity of 64%-95% and an accuracy of 78%-94% still very low. The EUS-FNB of pancreatic masses is usually performed with a 22-gauge biopsy needle. The small diameter of the needle is usually responsible for the low yield of tissue samples for histopathological examination. The 19-gauge needles help to overcome the limitations of a 22-gauge needle by acquiring a larger amount of cellular material. Thus, performing EUS-FNB with a 19-gauge needle can maximize tissue acquisition and sample adequacy, which is important for appropriate diagnosis. Contrariwise, the technical success rate for sample retrieval in patients with pancreatic head lesions is significantly lower using the 19-gauge compared to the 22-gauge needle. This is attributable to the technical difficulty to push the needle out of the endoscope in the duodenum. Since about 60% of pancreatic cancers are located in the head region, it is therefore particularly important to improve technical success in these cases. The new 19-gauge biopsy needle "Olympus EZ Shot3 Plus" is more flexible than common biopsy needles such as "EZ Shot2" and should therefore provide improved access to regions like pancreatic head. The aim of this multicenter prospective randomized crossover study is to compare those two needles during EUS-FNB of solid pancreatic masses. Therefore this study will enroll 40 patients in five German centers with solid pancreatic masses and consecutive indication for EUS-FNB. Both needles will be used in each patient following a predetermined random order. Primary endpoint is the correct histological diagnosis of the mass assessed by each needle. Technical failure is regarded as a negative histological diagnosis. Secondary endpoints include a comparison of technical failure using each needle, histological quality, duration of procedure and rate of adverse events.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | EUS-FNB with EZ Shot 3Plus first | Both needles (EZ Shot 3Plus 19G and EZ Shot 2 19G) will be used for endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) in each patient following a predetermined random order which needle is used to pass through the tumor first. |
| DEVICE | EUS-FNB with EZ Shot 2 19G first | Both needles (EZ Shot 3Plus 19G and EZ Shot 2 19G) will be used for endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) in each patient following a predetermined random order which needle is used to pass through the tumor first. |
Timeline
- Start date
- 2016-09-01
- Primary completion
- 2018-02-01
- Completion
- 2018-02-01
- First posted
- 2016-09-21
- Last updated
- 2019-02-22
Locations
4 sites across 1 country: Germany
Source: ClinicalTrials.gov record NCT02909530. Inclusion in this directory is not an endorsement.