Trials / Unknown
UnknownNCT02901353
A Prospective, Single-arm, Multi-centre, Observational, Real World Registry
A Prospective, Single-arm, Multi-centre, Observational, Real World Registry to Evaluate Safety and Performance of the BioMime™ Morph Sirolimus Eluting Coronary Stent System for Very Long Coronary Lesions.
- Status
- Unknown
- Phase
- —
- Study type
- Observational
- Enrollment
- 400 (estimated)
- Sponsor
- Meril Life Sciences Pvt. Ltd. · Industry
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
A prospective, single-arm, multi-centre, observational, real world registry to evaluate safety and performance of the BioMime™ Morph Sirolimus Eluting Coronary Stent System for very long coronary lesions.
Detailed description
Title: A prospective, single-arm, multi-centre, observational, real world registry to evaluate safety and performance of the BioMime™ Morph Sirolimus Eluting Coronary Stent System for very long coronary lesions. Short Title: Morpheus - Global Registry Sponsor: Meril Life Sciences Pvt. Ltd Device Used:BioMime™ Morph Sirolimus Eluting Coronary Stent System Study population: The utilization of the BioMime™ Morph Sirolimus Eluting Coronary Stent System implantation in very long (length ≤ 56 mm) coronary lesions in native coronary arteries with reference vessel diameter of 2.25 mm to 3.50 mm. Enrolment:Minimum 400 patients will be enrolled Clinical Sites:Minimum 15 sites Objectives:Purpose of this Registry is to evaluate safety and performance of the BioMime™ Morph Sirolimus Eluting Coronary Stent System in very long (length ≤ 56 mm) coronary lesions in native coronary arteries with reference vessel diameter of 2.25 mm to 3.50 mm. Study Design:This is a prospective, single-arm, multi-centre, observational, real world registry. All patients will be followed for up to 24 months. Primary Outcome Measures:Freedom of target lesion failure (TLF) at 6 month and up to 24 month TLF is defined as a composite of cardiac death, myocardial infarction and target lesion revascularization. Secondary Outcome Measures: 1. MACE at 1, 6, 12 and 24 month Defined as a composite of cardiac death, myocardial infarction attributed to the target vessel or Ischemia-driven TLR . 2. Target vessel failure at 1, 6, 12 and 24 month Defined as cardiac death, myocardial infarction attributed to the target vessel, or target vessel revascularization. 3. Academic Research Consortium (ARC) defined stent thrombosis at 1, 6, 12 and 24 months. Definite, probable and possible stent thrombosis during acute, subacute, late and very late phase. Other Outcome Measures: 1. Procedure Success: It is defined as angiographic evidence of \<30% final residual stenosis of the target lesion after stent placement and no occurrence of a procedure related MACE prior to hospital discharge (for subjects with more than one lesion stented, the worse case is counted) 2. Device Success: It is defined as angiographic evidence of \<30% final residual stenosis of the target lesion using only the assigned device
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | Sirolimus Eluting Coronary Stent System | Patient with Angina Pectoris will be enrolled for the intervention |
Timeline
- Start date
- 2017-02-02
- Primary completion
- 2020-12-01
- Completion
- 2022-12-01
- First posted
- 2016-09-15
- Last updated
- 2020-02-21
Locations
5 sites across 4 countries: Hungary, Jordan, Malaysia, Netherlands
Source: ClinicalTrials.gov record NCT02901353. Inclusion in this directory is not an endorsement.