Trials / Completed
CompletedNCT02892253
Parathyroid Autofluorescence Visualization in Thyroid Surgery: Impact on Postoperative Hypocalcemia
Parathyroid Autofluorescence Visualization in Thyroid Surgery: Impact on Postoperative Hypocalcemia. A Randomized Controlled Trial
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 241 (actual)
- Sponsor
- Hôpital Européen Marseille · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
This Multicenter, Randomized Controlled Trial evaluates the clinical impact of parathyroid autofluorescence visualization using near infrared light (NIR) during total thyroidectomy (TT). It compares patients who undergo TT associated or not with lymph node dissection (LND) with NIR vs without NIR use during surgery.
Detailed description
Total thyroidectomy (TT) is responsible for postoperative hypocalcemia in 20-30% of patients, which is definitive in 1-4% of operated patients (1). This complication is mainly due to surgery-induced parathyroid dysfunction, which could be improved by a better intraoperative identification of the parathyroids. Intraoperative parathyroid auto-fluorescence visualization (without any dye injection) using near infrared light (NIR) is an emerging technique, which allows correct identification of normal parathyroids in almost all cases (2), but the clinical impact of NIR is unknown. The aim of this prospective, comparative randomized study, is to compare 2 groups of patients: patients operated with NIR (NIR+) vs patients operated without NIR (NIR-). The main objective of this study is to assess the impact of intraoperative use of NIR camera on postoperative hypocalcemia. Secondary objectives are to assess the impact of NIR on the visualization, autotransplantation and inadvertent resection rates during TT.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | Near Infrared Camera (NIR) | Surgical field is examined with NIR, during a few minutes (\<5') with room lights switched off, to avoid parasite lights, then open thyroidectomy is resumed conventionally. Real-time images, evocative of autofluorescent parathyroids, are checked visually. NIR consists of a 750 nm class 1 laser excitation, with a power \<20mW/cm2 (5 times less than the limit of 100mw/cm2, fixed by the international standard IEC 60601-2-41). It is provided by the Fluobeam® camera, which is inserted into a sterile cover and hold at a 15-20 cm distance from the patient. The system has an FDA 510(k) authorization for clinical use in parathyroid surgery and a European Community certification (Class 2A device). |
Timeline
- Start date
- 2016-09-01
- Primary completion
- 2018-06-01
- Completion
- 2018-12-20
- First posted
- 2016-09-08
- Last updated
- 2019-01-07
Locations
3 sites across 1 country: France
Source: ClinicalTrials.gov record NCT02892253. Inclusion in this directory is not an endorsement.