Clinical Trials Directory

Trials / Terminated

TerminatedNCT02886546

Utility of Dynamic Variables Measured by Calibrated Pulse Contour Analysis of Oesophageal Doppler Monitor for Predicting Fluid Responsiveness During Robot-Assisted Laparoscopic Prostatectomy

Status
Terminated
Phase
N/A
Study type
Interventional
Enrollment
26 (actual)
Sponsor
Hallym University Kangnam Sacred Heart Hospital · Academic / Other
Sex
Male
Age
55 Years – 80 Years
Healthy volunteers
Accepted

Summary

Robot-assisted laparoscopic prostatectomy (RALP) is widely performed due to its many advantages, including a reduced need for blood transfusion and fewer surgical complications compared with conventional open prostatectomy. As this approach is also recommended in elderly patients with serious comorbidities, optimal fluid therapy guidance during this procedure is important. Dynamic variables such as pulse pressure variation (PPV) and stroke volume variation (SVV) are used to predict and guide fluid therapy during controlled ventilation. These variables arise from heart-lung interactions during positive pressure ventilation, which influence left ventricular stroke volume (SV). RALP requires carbon dioxide insufflation and the steep Trendelenburg position to optimise surgical conditions, and can reduce cardiac output and respiratory compliance. Accordingly, the usefulness of PPV and SVV, which are affected by changes in intrathoracic pressure, in predicting fluid responsiveness during laparoscopic surgery under these conditions may be questioned. A recent study established that PPV and SVV derived by uncalibrated pulse contour analysis had a relatively poor capacity to predict fluid responsiveness during laparoscopy on dynamic preload indices. In contrast, another study SVV measured by oesophageal Doppler monitor (ODM) could predict fluid responsiveness during laparoscopic surgery. The CardioQ-ODM+ combines the proven ODM Doppler measurement of blood flow with pulse contour analysis, which is quickly and easily calibrated from the Doppler signal. We hypothesized that PPV and SVV measured by calibrated pulse contour analysis would be a good indicator of fluid responsiveness during laparoscopy with pneumoperitoneum. The primary objective of this study was to demonstrate that PPV and SVV measured by calibrated pulse contour analysis of CardioQ-ODM+ can accurately predict fluid responsiveness during RALP, which involves both pneumoperitoneum and the Trendelenburg position. Investigators also assessed the capacity of other dynamic variables (SPV \[systolic pressure variation\], and SVV determined by ODM Doppler flow, dynamic elastance \[PPV/SVV\] and corrected flow time \[FTc\]) to predict fluid responsiveness during RALP.

Conditions

Interventions

TypeNameDescription
PROCEDUREpneumoperitoneum
DEVICEoesophageal Doppler monitor

Timeline

Start date
2016-09-01
Primary completion
2017-09-01
Completion
2017-09-01
First posted
2016-09-01
Last updated
2026-01-30

Source: ClinicalTrials.gov record NCT02886546. Inclusion in this directory is not an endorsement.

Utility of Dynamic Variables Measured by Calibrated Pulse Contour Analysis of Oesophageal Doppler Monitor for Predicting (NCT02886546) · Clinical Trials Directory